Since 1999 · Cangzhou, Hebei

Sectional Doors · Manufacturer since 1999

Sectional Door with Wicket Door

Also searched as: Industrial Door with Pedestrian Wicket Door

Any Size · Custom Engineered CE · EN 13241 100,000-Cycle Tested Full technical drawings
Sectional Door with Wicket Door — RAX Door Technology
01 · Overview

Sectional Door with Wicket Door at a Glance

The Sectional Door with Wicket Door integrates a pedestrian access door within the main sectional panel assembly — allowing personnel to enter and exit without opening the full door. This saves energy (reducing heat loss in conditioned buildings), improves traffic flow in busy logistics bays, and provides a fire-escape route where required by building code. The wicket door is hinged within the bottom panel section and includes its own lockset, closer and safety interlock.

RAX manufactures sectional doors with integrated wicket doors to any opening size (custom engineered to your specification), using 40–50 mm PU foam panels with galvanized steel skins (0.4–1.5 mm). The wicket frame is reinforced to maintain panel structural integrity, and a safety interlock prevents the main door from operating while the wicket is open — a requirement of EN 12453 for power-operated doors. Standard wicket widths are 800–1200 mm; custom sizes available.

RAX-company facts on this page are from the approved brand brief. Industry benchmark values are attributed to their sources (Hörmann via renrendoc.com; CN-export listings via ecer.com; EN standard scopes via antpedia.com / baijiahao). RAX product-specific test data (U-value, wind class, fire rating) is confirmed per project.

02 · Key Features

Key Features & Benefits

Made to Your Opening

Custom width × height, RAL color and configuration. Large industrial doors from prototype to container-load, full flexibility on order quantity.

Durable by Test

Validated against a 100,000-cycle fatigue testing protocol in our in-house lab.

Certified & Documented

ISO 9001:2015 and CE to EN 13241 / EN 12453, with SGS material reports.

Install-Ready Package

English manual + wiring diagrams; operators pre-set before dispatch.

03 · Technical Data

Technical Specifications

ProductSectional Door with Wicket Door (also: Sectional Door with Pedestrian Door · Personnel Access Sectional Door)
CategorySectional Doors
Wicket doorIntegrated hinged pedestrian door within bottom panel; 800–1200 mm width (custom available)
Safety interlockPrevents main door operation while wicket is open (EN 12453 requirement)
Panel thickness40–50 mm PU foam (RAX capability)
Steel skinGalvanized steel 0.4–1.5 mm
Wicket hardwareLockset, door closer, hinges — stainless or galvanized. Panic hardware available
Size rangeCustom main door + wicket (custom engineered to your specification)
Torsion springHigh-cycle; 100,000-cycle fatigue validated
PowerAC 220–240 V, 50/60 Hz. Operator with wicket-interlock integration
CertificationCE EN 13241 / EN 12453 (held); ISO 9001:2015; SGS
OrderCustom engineered to your size and specification
04 · Engineering Delivery

How to Specify (Buyer Guide)

1. Wicket Position & Size

Specify wicket position (center or offset) and width (standard 800–1200 mm). The wicket is located in the bottom panel section. Confirm swing direction (inward/outward) and whether panic hardware is required for fire escape.

2. Safety Interlock

A mandatory safety switch prevents the main door operator from running while the wicket is open. RAX integrates the interlock with the operator control panel and includes it in the wiring diagrams.

3. Sealing & Insulation

The wicket door includes its own perimeter seal to maintain the main door’s thermal and air-permeability performance. Specify the same 40–50 mm PU panel build for consistent insulation.

4. Access Control

Options: mechanical lockset, electronic access control, panic bar (fire escape). For logistics facilities, specify whether the wicket needs to accommodate trolley/pallet-jack width.

05 · Customization

OEM / ODM & Customization

RAX supports full private-label production of the Sectional Door with Wicket Door: custom RAL panel colors, operator matching, packaging printing and installation-manual translation (EN/ES/FR/AR/RU). Start with an OEM sample and scale to container-load branded production. Custom molds, Tooling records are archived for up to 5 years — no extra tooling fee on repeat orders, all under strict NDA.

06 · Compliance

Applicable Standards

EN 13241

CE marking basis. Wicket doors within industrial doors fall under the same product standard requirements.

EN 12453

Power-operated safety — the wicket interlock is a specific requirement: the main door must not operate while the pedestrian door is open.

EN 12604

Mechanical aspects — wicket hinges, frame reinforcement and structural integrity of the modified panel.

07 · Why RAX

Sectional Door with Wicket Door at a Glance

  • 100,000-Cycle Durability Guarantee
  • Any Size, Any Spec — Deep Customization
  • RAL Color-Consistent Batch Production
  • From Custom Engineering to Container-Load Delivery
What is a wicket door in a sectional door?

A wicket door is a pedestrian access door built into the main sectional panel (usually the bottom section). It allows personnel to enter/exit without raising the full door — saving energy and improving traffic flow in busy facilities.

Is a safety interlock required?

Yes — EN 12453 requires that the main door operator cannot run while the wicket is open. RAX integrates a safety interlock switch as standard, wired into the operator control panel.

Does the wicket compromise insulation?

The wicket door includes its own perimeter seal and uses the same 40–50 mm PU panel construction as the main door. Thermal performance is maintained, though the wicket frame creates a minor thermal bridge that is addressed with thermal-break profiles.

What wicket sizes are available?

Standard widths 800–1200 mm; custom sizes available. Height is determined by the bottom panel section. For trolley/pallet-jack access, specify the required clear width.

Do you provide installation?

No — pure manufacturer. Ships with English manual, wiring diagrams (including interlock wiring). Wicket hardware pre-fitted.

What is the lead time?

Standard container 12–20 days; custom first order 20–35 days. Door body 2-year warranty, operator 3 years.

Or email info@raxdoor.com

09 · Get Started

Get Your Sectional Door with Wicket Door Proposal

Send your opening size and duty requirements — we reply with a proposal and lead time.

Back to top
Need a fast quotation? Chat with our export team on WhatsApp.