The Cleanroom High Speed Door is engineered to protect pressure differentials and limit particle transfer at openings in controlled environments. Its value is air-tightness plus fast, repeatable cycling – so the room stays within class while people, trolleys and AGVs pass through – rather than generating cleanliness itself.
Cleanroom rapid doors typically target ISO Class 5-8 (GMP grade C/D is roughly ISO 7-8). ISO 14644-1 sets the particle limits – for example ISO 7 allows 352,000 particles/m3 at 0.5 micron and ISO 8 allows 3,520,000. RAX engineers the door for air-tightness and fast cycling to support your target class; the cleanroom class achieved by the installed assembly needs third-party verification, so RAX does not claim a specific ISO class as a tested RAX result.
As a pure manufacturer, RAX builds each cleanroom high speed door to your exact opening and RAL color – from prototype to container-load delivery order – with wiring diagrams and English manuals for your local installers.
Sources & honesty: RAX-company facts on this page (materials, 100,000-cycle fatigue testing, certifications held, warranty, lead time) are from RAX Door Technology’s approved brand brief. Industry benchmark figures (typical opening speeds, cycle-life ranges, EN 12424 wind classes, ISO 14644-1 cleanroom classes, competitor reference points) are drawn from our sourced category research (research/high-speed-doors.md) and are marked as industry-typical or attributed to the named manufacturer. RAX’s own measured speed, U-value, wind-class certificate and cleanroom class are confirmed per project by test – we do not publish them as generic figures. Fire resistance (EN 1634-1) and ATEX suitability are project-specific capabilities, not blanket certificates.
Tight peripheral sealing and rapid operation help hold room pressure differentials and limit particle transfer (air-permeability confirmed per project).
Smooth, easy-clean curtain/panels and stainless 304/316 hardware options for controlled environments.
Closed-loop servo for precise, repeatable cycling – manufactured in-house by RAX.
Seals and drive validated against RAX’s 100,000-cycle fatigue protocol; servo motor backed by a 5-year warranty.
| Product | Cleanroom High Speed Door |
| Category | High Speed Doors |
| Curtain / panel | Smooth PVC coated fabric 0.9-1.2 mm or rigid panels (RAX); stainless 304/316 hardware; full RAL / clean-compatible finishes. |
| Target cleanroom class | Engineered to support ISO Class 5-8 (GMP grade C/D ~ ISO 7-8). ISO 14644-1 particle limits, e.g. ISO 7 = 352,000/m3 @0.5 micron; ISO 8 = 3,520,000. Class achieved by the installed assembly needs third-party verification (not claimed as a RAX test result). |
| Sealing / air-tightness | Tight peripheral and bottom sealing to hold pressure differentials; air-permeability within EN 13241 scope (value per project). |
| Opening speed | Rapid, repeatable cycling to limit air exchange; exact RAX speed confirmed per project (market rapid doors broadly span ~0.6-2.0 m/s by type – industry synthesis). |
| Drive system | Closed-loop servo (recommended for repeatable cycling) or VFD – RAX capability; 220V / 380V, 50/60Hz. |
| Cycle life | Validated against RAX’s 100,000-cycle fatigue protocol; industry servo design life commonly 150,000-500,000+ cycles (estimate). |
| Safety devices | Anti-pinch safety edge, photo eyes; optional light curtain, radar and geomagnetic sensing (RAX capability). |
| Operating temperature | RAX products tested -30 C to +50 C; suited to conditioned controlled environments. |
| Max opening | Custom to your opening – feasible span confirmed by our engineers. |
| Certification | CE EN 13241 / EN 12453 (held); cleanroom class verification by third party per project. |
| Order | Custom engineered to your exact opening, specification and RAL color |
Provide clear opening width x height, headroom and side room – or site photos. We produce the confirmation drawing and confirm the feasible span against wind class.
Cycles per day, operating temperature range, wind exposure, and clean / cold / washdown / hazardous-area duty.
Target speed, thermal (U-value), wind (EN 12424), fire (EN 1634-1), acoustic or cleanroom class – we match the applicable standard and confirm by test.
Servo or VFD drive, sensing (radar / geomagnetic / light-curtain), safety edges and any safety-interlock or smart (WiFi/RS485) control needs.
GMP grade C/D zones where pressure differentials and particle control matter.
ISO Class 5-8 controlled environments for sensitive manufacturing.
Clean partitions between production, assembly and packaging.
Hygienic controlled areas needing air-tight, fast-cycling doors.
RAX supports full private-label production of the Cleanroom High Speed Door: custom RAL panel colors, operator matching, packaging printing and installation-manual translation (EN/ES/FR/AR/RU). Start with an OEM sample and scale to container-load branded production. Custom molds, Tooling records are archived for up to 5 years — no extra tooling fee on repeat orders, all under strict NDA.
Product standard for industrial, commercial and garage doors – the harmonized basis for CE marking. Covers mechanical and power-operated safety, wind-pressure and water-penetration resistance, thermal (U-value) and air-permeability performance, with technical documentation retained 10 years.
Safety in use of power-operated doors – operating-force limits and entrapment protection, and the test methods behind our operator safety data.
Cleanroom air-cleanliness classification by particle count (ISO Class 1-9) – e.g. ISO 7 = 352,000 particles/m3 at 0.5 micron; ISO 8 = 3,520,000. The door’s role is air-tightness and fast cycling to hold pressure differentials.
Any opening size within the High Speed Doors range – large industrial doors from prototype to container-load, full flexibility on order quantity. Share your opening width x height (or site photos) and our engineers confirm the feasible span, wind class and drive sizing, then produce technical drawings.
Cleanroom rapid doors prioritize fast, repeatable cycling and air-tightness over maximum speed; market rapid doors broadly span ~0.6-2.0 m/s by type (industry synthesis). RAX confirms the travel speed and sealing for your room in the quotation.
The door’s job is to be air-tight and to cycle fast so the room holds its pressure differential and class – it does not generate cleanliness itself. Cleanroom rapid doors typically target ISO Class 5-8 (GMP grade C/D ~ ISO 7-8) under ISO 14644-1. The class achieved by the installed assembly depends on the whole room and needs third-party verification, so RAX engineers the door to support your target class rather than claiming a specific ISO class as a tested RAX result.
We are a pure manufacturer and do not provide on-site installation. Every order ships with an English installation manual, wiring diagrams for your local installation team; operators are pre-set and tested before dispatch.
RAX holds ISO 9001:2015 and CE to EN 13241 (industrial door) and EN 12453 (operator safety), with SGS material reports and product liability insurance. Fire resistance (EI60/EI120) and an EN 12424 wind-load class are project-specific capabilities we test and certify per order against the matching standard – we do not overclaim a blanket rating.
Yes. RAL panel colors, operator matching, packaging printing and manual translation (EN/ES/FR/AR/RU) are all supported, from an OEM sample to container-load branded production, under strict NDA.
Sample 7-15 days; standard container 12-20 days; custom first order 20-35 days. Door body 2-year warranty, operator/motor 3 years (servo motor 5 years), with spare parts dispatched by DHL/FedEx within warranty.
Factory inspection report (speed, noise, insulation-resistance and visual tests), 100,000-cycle fatigue test video/report, FAI / pre-assembly photos, English installation manual + wiring diagrams, CE Declaration of Conformity with EN 13241 test report, and export packing (steel frame + pearl cotton + stretch film).
Or email info@raxdoor.com
Send your opening size and duty requirements — we reply with a proposal and lead time.