Since 1999 · Cangzhou, Hebei

Door Operators · Manufacturer since 1999

Fire Door Operator

Fire-Rated · Automatic Closing CE · EN 13241 Full technical drawings
Fire Door Operator — RAX Door Technology
01 · Overview

Automatic Fire Door Closure Systems

Fire door operators are automatic closing systems designed for fire-rated doors. Unlike standard door operators that focus on convenience, fire door operators prioritize safety — automatically closing fire doors when fire alarms are triggered, maintaining fire compartmentalization and protecting escape routes.

RAX manufactures fire door operators with fail-safe closing mechanisms, fire alarm integration, and backup battery systems. Operators are compatible with various fire door types including swing, sliding, and rolling doors. Compliance with EN 16034 and EN 1154 standards.

These operators are essential for commercial buildings, hospitals, schools, industrial facilities with fire compartments, and any environment where automatic fire door closure is required by building codes.

02 · Key Features

Engineered for Fire Safety

Fail-Safe Closing

Automatic closing when fire alarms are triggered. Fail-safe mechanism ensures door closes even during power failure. Critical for maintaining fire compartmentalization during emergencies.

Fire Alarm Integration

Direct integration with building fire alarm systems. Immediate response to fire detection. Compliant with EN 16034 fire door product standard requirements.

Backup Battery System

Built-in battery backup ensures operation during power failure. Critical for fire safety when power grids may be compromised during fire events.

Adjustable Closing Speed

Programmable closing speed and force. Meets EN 1154 requirements for controlled door closing. Prevents injury during emergency evacuation.

Universal Compatibility

Compatible with swing, sliding, and rolling fire doors. Flexible mounting options for various door configurations. Suitable for retrofit and new construction.

Compliance Documentation

Full compliance documentation for EN 16034 and EN 1154. Suitable for building code compliance and fire safety audits.

03 · Technical Data

Technical Specifications

Fail-safe mechanism, adjustable force, emergency release

EN 16034 (fire door product standard); EN 1154 (controlled door closing devices); CE marking

Custom engineered to your fire door type and building code requirements

ProductFire Door Operator (also: Automatic Fire Door Closer · Fire Safety Door Operator)
CategoryDoor Operators
Operation typeFail-safe automatic closing
Fire alarm integrationDirect integration with building fire alarm systems
Backup powerBuilt-in battery backup system
Closing speedAdjustable (compliant with EN 1154)
Door compatibilitySwing, sliding, and rolling fire doors
Safety features
Certification
Order
04 · Applications

Where Fire Door Operators Excel

Commercial Buildings

Office buildings and retail spaces with fire compartment requirements. Automatic closing maintains fire safety during emergencies. Compliant with building codes.

Hospitals

Healthcare facilities with strict fire safety requirements. Automatic closing protects escape routes. Fail-safe mechanism ensures operation during power failure.

Schools

Educational facilities with fire safety requirements. Automatic closing protects students and staff. Adjustable closing speed prevents injury during evacuation.

Industrial Facilities

Manufacturing plants with fire compartments. Automatic closing maintains fire compartmentalization. Compatible with various fire door types.

Hotels

Hospitality facilities with fire safety requirements. Automatic closing protects guest escape routes. Backup battery ensures operation during power failure.

Public Buildings

Government buildings, libraries, and community centers. Automatic closing meets building code requirements. Compliance documentation for fire safety audits.

05 · Customization

OEM / ODM & Customization

RAX supports full private-label production of the Fire Door Operator: custom closing speed, fire alarm integration protocol, backup battery capacity, mounting configuration, packaging printing and installation-manual translation (EN/ES/FR/AR/RU). Start with an OEM sample and scale to container-load branded production. Custom molds and tooling records are archived for up to 5 years — no extra tooling fee on repeat orders, all under strict NDA.

06 · Compliance

Applicable Standards

EN 16034

EU product standard for fire and smoke doors. Covers fire resistance, smoke control, and durability. Fire door operators must comply with automatic closing requirements.

EN 1154

Controlled door closing devices standard. Specifies requirements for closing speed, force, and safety. Fire door operators must meet EN 1154 requirements.

EN 13241:2003+A2:2016

Core CE product standard for industrial, commercial, and garage doors. Fire door operators must comply with general safety requirements.

CE Marking

Mandatory for export to EU/UK markets. RAX provides CE technical file, Declaration of Performance, and compliance documentation with every shipment.

07 · Why RAX

Why Buyers Choose RAX for Fire Door Operators

  • 27-year zero-leak track record — 5,000+ overseas projects delivered since 1999, with no leakage complaints on door bodies
  • Fail-safe closing — automatic closing when fire alarms are triggered, even during power failure
  • Fire alarm integration — direct integration with building fire alarm systems
  • Backup battery system — ensures operation during power failure
  • Deep customization — every operator engineered to your fire door type and building code requirements
  • Full documentation package — English installation manual, compliance documentation, CE technical file
How does fail-safe closing work?

Automatic closing when fire alarms are triggered. Fail-safe mechanism ensures door closes even during power failure. Critical for maintaining fire compartmentalization during emergencies.

Can fire door operators integrate with existing fire alarm systems?

Yes. Direct integration with building fire alarm systems. Immediate response to fire detection. Compliant with EN 16034 fire door product standard requirements.

What happens during power failure?

Built-in battery backup ensures operation during power failure. Critical for fire safety when power grids may be compromised during fire events.

Are fire door operators compatible with all fire door types?

Compatible with swing, sliding, and rolling fire doors. Flexible mounting options for various door configurations. Suitable for retrofit and new construction.

Do you provide installation?

No — RAX is a pure manufacturer. Operators ship with English installation manuals, wiring diagrams, and remote support.

What is the lead time and warranty?

Standard configurations: 12–20 days. Custom first order: 20–35 days. Repeat orders: 15–20 days. Warranty: operator 5 years, battery 2 years.

09 · Get Started

Get Your Fire Door Operator Proposal

Send your fire door type, building code requirements, and fire alarm system details — we reply with a specification, lead time, and quote.

Back to top
Need a fast quotation? Chat with our export team on WhatsApp.