The Roll Up Garage Door (roller shutter garage door) consists of horizontal slats that coil around a drum above the opening, requiring minimal headroom and no ceiling track run. This makes roll-up doors ideal for garages with very limited internal space, short driveways where swing-out clearance is unavailable, and applications where the ceiling must remain completely clear for storage or services.
RAX manufactures roll-up garage doors as part of its full-category product range (sectional doors, roller shutters, high-speed doors, all operators and spring parts in one factory). Slats are formed from galvanized steel (0.4–1.5 mm) or aluminum alloy 6063-T5, with optional PU foam filling for thermal and acoustic insulation. The compact coil box sits within the opening reveal or above the lintel. For industry context, insulated roller shutter slats commonly use 40–48 kg/m³ PU foam fill (industry estimate). RAX validates cycle life in its 100,000-cycle fatigue lab and provides full RAL color customization.
RAX-company facts on this page are from the approved brand brief. Industry benchmark values are attributed to their sources (Hörmann via renrendoc.com; CN-export listings via ecer.com; EN standard scopes via antpedia.com / baijiahao). RAX product-specific test data (U-value, wind class, fire rating) is confirmed per project.
Custom width × height, RAL color and configuration. Large industrial doors from prototype to container-load, full flexibility on order quantity.
Validated against a 100,000-cycle fatigue testing protocol in our in-house lab.
ISO 9001:2015 and CE to EN 13241 / EN 12453, with SGS material reports.
English manual + wiring diagrams; operators pre-set before dispatch.
| Product | Roll Up Garage Door (also: Roller Shutter Garage Door · Rolling Garage Door · Coil Garage Door) |
| Category | Sectional Doors |
| Slat material | Galvanized steel 0.4–1.5 mm or aluminum 6063-T5 (RAX capability) |
| Insulation | Optional PU foam-filled slats (closed-cell, 40–48 kg/m³ industry-typical density) |
| Coil box | Compact box within reveal or above lintel; minimal headroom required |
| Size range | Custom to your opening (custom engineered to your specification). Standard garage widths to approx. W5000 mm |
| Color | Full RAL custom; PVDF coating for exterior durability |
| Operator | Tubular motor (in-shaft) or external chain-drive. AC 220–240 V, 50/60 Hz |
| Torsion spring | Spring-assisted or fully motorized; 100,000-cycle fatigue validated |
| Safety | Anti-drop brake, bottom sensor, photo-eye |
| Certification | CE EN 13241 / EN 12453 (held); ISO 9001:2015; SGS |
| Order | Custom engineered to your size and specification |
Roll-up doors require minimal headroom — just the coil-box height (typically 300–450 mm depending on door height). Confirm whether the box sits inside the reveal or above the lintel. We provide coil-box dimension drawings.
Choose slat material (steel for security, aluminum for weight/corrosion) and whether PU foam filling is needed for thermal/acoustic insulation. Foam-filled slats improve U-value and reduce noise.
Tubular motor (compact, in-shaft) for standard garages; external chain-drive for heavier doors. Specify remote control, keypad or smart WiFi operation.
Roll-up doors provide inherent security (interlocking slats, anti-lift locking). Specify additional locking, alarm integration or access control as needed.
RAX supports full private-label production of the Roll Up Garage Door: custom RAL panel colors, operator matching, packaging printing and installation-manual translation (EN/ES/FR/AR/RU). Start with an OEM sample and scale to container-load branded production. Custom molds, Tooling records are archived for up to 5 years — no extra tooling fee on repeat orders, all under strict NDA.
CE marking basis. Roller shutter garage doors fall under the same product standard as sectional doors.
Power-operated safety and mechanical aspects. Anti-drop braking and force limiting apply to motorized roller shutters.
Roll-up doors require minimal headroom (just the coil box) and no ceiling track — ideal for garages with very limited internal space or where the ceiling is used for storage. Sectional doors provide better insulation (thicker panels) and wider design options.
Typically 300–450 mm for the coil box (depending on door height and slat profile). Significantly less than a sectional door’s track system. RAX provides exact coil-box dimensions in technical drawings.
Yes — PU foam-filled slats provide thermal and acoustic insulation. Foam density is typically 40–48 kg/m³ (industry estimate). However, overall thermal performance is generally lower than a 40–50 mm sectional panel due to thinner slat construction.
Steel slats offer higher security and impact resistance; aluminum slats are lighter (easier on the motor), corrosion-resistant and available in more finish options. RAX provides both in 0.4–1.5 mm gauge with full RAL color.
No — pure manufacturer. Ships with English manual, wiring diagrams. Operators pre-set before dispatch.
Standard container 12–20 days. Door body 2-year warranty, operator 3 years (servo 5 years).
Or email info@raxdoor.com