Steel industrial doors engineered to a fire integrity and insulation rating for compartmentation — closing large openings that must hold back fire and smoke.
A fire-rated steel door built to compartmentalize your building, with the rating engineered and tested per project to the matching standard. Custom built from prototype to container-load, full order flexibility, with full technical and CE documentation.
Fire compartmentation only works if the big openings close with a rated door. This range turns a large steel closure into a tested fire barrier.
Walls are rated to hold back fire for a defined period, and every opening in them must match. A fire-rated industrial steel door protects large compartment openings — between production bays, storage and escape routes — with a steel leaf, fire-resilient core and intumescent seals that expand under heat to close the gaps.
Fire rating is a per-project capability at RAX: the integrity-and-insulation class (such as EI60 or EI120) is engineered to your specification and validated by test against the matching standard, rather than claimed as a blanket certificate. Configuration can be sliding, sectional or swing, selected to the opening and the required rating.
RAX company facts are from the approved brand brief. Fire rating (EI60 / EI120) is a per-project capability, tested against the matching standard — not a held blanket certificate.
Every door is engineered to your opening. The values below are the validated baseline; final figures are confirmed on your specification.
| Parameter | Specification | Basis |
|---|---|---|
| Door Type | Sliding, sectional or swing fire-rated steel door, selected to opening and rating. | Per project |
| Fire Rating | Integrity & insulation classes such as EI60 / EI120, engineered and tested per project. | Per project |
| Test Standard | Fire resistance tested against the matching standard (e.g. EN 1634-1) for the project. | Per project |
| Leaf | Galvanized steel sheet (0.4–1.5 mm) over a fire-resilient mineral core. | RAX-measured |
| Sealing | Intumescent seals expand under heat; smoke seals on request. | RAX |
| Opening Size | Made to order; large compartment openings engineered to the rating. | Per project |
| Cycle Life | 100,000 cycles validated in the RAX fatigue test lab. | RAX-measured |
| Operation | Manual or electric operator with servo / VFD drive; fail-safe closing options. | RAX |
| Safety | Anti-pinch safety edge, fusible-link / detector-triggered closing on request. | RAX |
| Finish | Full RAL custom; powder-coated steel for durable, cleanable faces. | RAX |
Send your required fire class and opening size — we confirm the construction, test standard and hardware on the technical layout before production.
Validated substrates, processed in-house on an auto PU foam panel line and CNC punching/bending centre.
Match the door to the opening duty — keep each card to one line.
Your installers get the full document set before the door ships.
Certificates we hold today, and the project-specific test data we arrange against the matching standard.
Rigorous 100,000-cycle fatigue testing protocols, validated galvanized steel and aluminum alloy materials, and precision servo-drive manufacturing — documented on every order.
Large industrial doors from prototype to container-load delivery.
OEM/ODM is the core of what we do: fire class, configuration, opener matching and manual translation are all tailored to your project and market — under NDA protection.
From custom engineering to container-load delivery — the document set your local installers need.
Door body 2 years · operator / motor 3 years (servo motor 5 years) · free spare parts within warranty, DHL/FedEx 5–7 days · tooling & technical drawings archived up to 5 years.
Fire rating is a per-project capability: integrity-and-insulation classes such as EI60 and EI120 are engineered to your specification and validated by test against the matching standard. We do not claim a blanket certificate — the rating is confirmed and documented for your specific door and opening.
Fire resistance is tested against the matching standard for the project, such as EN 1634-1. Tell us the standard and class your authority requires and we scope the construction and test data accordingly.
Sliding, sectional and swing steel doors can all be built as fire-rated assemblies. We recommend the configuration to suit the opening size, the required rating and how the door is used day to day.
Yes. Fail-safe closing options include detector-triggered and fusible-link release so the door closes on a fire signal, and smoke seals can be added to restrict smoke spread. We specify the release and safety devices to match your fire strategy.
Yes. We hold CE to EN 13241 and EN 12453 for operator safety, backed by ISO 9001:2015 and SGS material reports. Fire resistance test data is arranged per project. A Declaration of Conformity and test report ship with every order.
Every door is custom-engineered to your specification. Samples run 7–15 days, a standard container 12–20 days, and a first custom order 20–35 days (repeat orders 15–20 days). FOB ports are Tianjin and Qingdao, FCL and LCL.
Door body is covered for 2 years and the operator / motor for 3 years (servo motor 5 years). Free spare parts within warranty ship by DHL/FedEx in 5–7 days, and OEM projects are protected under NDA.
Send your required fire class, standard and opening size — we return a technical layout, specification and container-ready quotation.