The PU Insulated Sectional Door is RAX Door Technology’s core thermal-performance product for logistics warehouses, food-processing facilities and energy-conscious industrial buildings. Each door is built with 40–50 mm thick closed-cell polyurethane (PU) foam panels — the same insulation technology that premium European brands such as Hörmann use in their EPU/LPU ranges (Hörmann specifies 42 mm panels with CFC-free PU foam). RAX produces panels on an automated PU foam line, ensuring consistent foam density and bond quality across every batch.

For reference, a comparable CN-export industrial sectional door lists 40 mm panels at 46 kg/m³ foam density, achieving a thermal transmittance of 0.38 W/m²K (source: ecer.com industrial listing). RAX’s own marketing target is U-value 0.33 W/m²K thermal performance — this is a design goal pending RAX’s own EN-tested whole-door U-value report and should not be cited as a certified lab result. Steel skins range from 0.4 to 1.5 mm galvanized sheet (brand capability); for comparison, Hörmann uses 0.7–0.75 mm steel skins on its EPU40/LPU40 panels.

RAX-company facts on this page are from the approved brand brief. Industry benchmark values are attributed to their sources (Hörmann via renrendoc.com; CN-export listings via ecer.com; EN standard scopes via antpedia.com / baijiahao). RAX product-specific test data (U-value, wind class, fire rating) is confirmed per project.

02 · Key Features

Key Features & Benefits

Made to Your Opening

Custom width × height, RAL color and configuration. Large industrial doors from prototype to container-load, full flexibility on order quantity.

Durable by Test

Validated against a 100,000-cycle fatigue testing protocol in our in-house lab.

Certified & Documented

ISO 9001:2015 and CE to EN 13241 / EN 12453, with SGS material reports.

Install-Ready Package

English manual + wiring diagrams; operators pre-set before dispatch.

03 · Technical Data

Technical Specifications

ProductPU Insulated Sectional Door (also: PU Insulated Steel Sectional Door · Standard Lift Sectional Door · Overhead Sectional Door)
CategorySectional Doors
Panel thickness40–50 mm closed-cell PU foam (RAX capability). Industry benchmark: Hörmann EPU/LPU 42 mm; CN-export standard 40 mm
Foam densityClosed-cell polyurethane, CFC-free. Industry benchmark: 46 kg/m³ (CN-export listing, ecer.com); typical range 40–48 kg/m³
Thermal (U-value)Marketing target: 0.33 W/m²K (pending RAX EN test report). Benchmarks: CN-export 0.38 W/m²K; Hörmann 0.5–1.3 W/m²K depending on configuration
Steel skinGalvanized steel 0.4–1.5 mm (RAX range). Benchmark: Hörmann 0.7–0.75 mm; CN-export 0.4 mm
Size rangeCustom to your opening. Industrial sectional doors commonly reach W8000 × H6000 mm+ (vertical-lift higher). Confirm feasible span with RAX engineers
Lift typeStandard lift (horizontal track after vertical rise). Also available: high lift, vertical lift, low-headroom
Torsion springHigh-cycle torsion springs; validated in RAX 100,000-cycle fatigue test lab. Industry benchmark: 30,000 cycles (CN-export, ecer.com)
Color / finishFull RAL custom (common RAL9006 / 9010 / 7016 / 5010), wood-grain transfer, PVDF coating, anodizing. Panel surface: flat / ribbed / cassette / orange-peel
PowerAC 220–240 V, 50/60 Hz (industry standard). 380 V three-phase for heavy-duty operators. WiFi/RS485 smart control available
SealingPerimeter EPDM/silicone rubber seals; air permeability tested per EN 12207 framework. Bottom air-bag sensor available
CertificationCE EN 13241 / EN 12453 (held); ISO 9001:2015 (held); SGS material reports (held). Wind class per EN 12424 confirmed per project
OrderCustom engineered to your exact opening, specification and RAL color
04 · Engineering Delivery

How to Specify (Buyer Guide)

1. Opening & Headroom

Provide clear opening width × height and available headroom (distance from lintel to ceiling). Standard lift requires approx. 300–600 mm headroom; we produce the confirmation drawing showing exact track geometry.

2. Thermal Target

Specify your required U-value or energy-code compliance. For insulated logistics buildings, a 40–50 mm PU panel is standard. We match panel build and perimeter sealing to your climate zone and confirm against EN 12428 thermal calculation.

3. Cycle Duty

State expected cycles/day. For 10+ cycles/day logistics use, specify high-cycle torsion springs (validated to 100,000 cycles in our fatigue lab). Standard residential-grade springs (approx. 10,000 cycles) are not suitable for industrial duty.

4. Finish & Aesthetics

Choose RAL color (batch-consistent production), panel surface profile (flat/ribbed/cassette/orange-peel) and optional wood-grain transfer. Interior face standard is light grey; exterior to your brand palette.

05 · Customization

OEM / ODM & Customization

RAX supports full private-label production of the PU Insulated Sectional Door: custom RAL panel colors, operator matching, packaging printing and installation-manual translation (EN/ES/FR/AR/RU). Start with an OEM sample and scale to container-load branded production. Custom molds, Tooling records are archived for up to 5 years — no extra tooling fee on repeat orders, all under strict NDA.

06 · Compliance

Applicable Standards

EN 13241

Product standard for industrial, commercial and garage doors — the harmonized basis for CE marking. Covers mechanical safety, thermal resistance (U-value), air permeability, water penetration, wind resistance and durability. Technical docs retained 10 years.

EN 12453 / EN 12604

Safety in use of power-operated doors (operating forces, entrapment protection) and mechanical aspects (panel joints, springs, tracks). Together they define finger-safe geometry and controlled operating forces.

EN 12424 / EN 12444

Wind load resistance classification (Class 0–5) and test method. Class 0 = none (internal/shielded); Class 5 = exceptional, >1000 Pa by special agreement. Confirm required class for your site wind exposure.

EN 12207

Air permeability classification framework. Perimeter sealing design targets low air-leakage for energy compliance in conditioned warehouses and cold-chain buffer zones.

07 · Why RAX

PU Insulated Sectional Door at a Glance

  • 100,000-Cycle Durability Guarantee
  • Any Size, Any Spec — Deep Customization
  • RAL Color-Consistent Batch Production
  • From Custom Engineering to Container-Load Delivery
What panel thickness and foam density does RAX use?

RAX produces 40–50 mm closed-cell PU foam panels on an automated foam line. For reference, a comparable CN-export industrial door uses 40 mm panels at 46 kg/m³ density (ecer.com listing), while Hörmann specifies 42 mm CFC-free PU panels. Exact foam density per RAX product is confirmed on request with SGS material report.

Is the 0.33 W/m²K U-value a certified test result?

No. The 0.33 W/m²K figure is RAX’s marketing design target for thermal performance. It is pending RAX’s own EN-tested whole-door U-value report. For context, a comparable CN-export door lists 0.38 W/m²K, and Hörmann’s EPU40/LPU40 achieves 0.5–1.3 W/m²K depending on panel/joint/glazing configuration. We will provide our test report once available.

What torsion spring cycle life can I expect?

RAX validates springs in its in-house 100,000-cycle fatigue test lab. Industry benchmarks: standard residential springs approx. 10,000 cycles; mid-grade industrial 30,000 cycles (CN-export listing, ecer.com); high-cycle industrial 50,000–100,000+. Specify your cycles/day and we match the appropriate spring rating.

Do you provide installation for the PU Insulated Sectional Door?

We are a pure manufacturer and do not provide on-site installation. Every order ships with an English installation manual, wiring diagrams for your local installation team; operators are pre-set and tested before dispatch.

What certifications does this door carry?

RAX holds ISO 9001:2015 and CE to EN 13241 (industrial door) and EN 12453 (operator safety), with SGS material reports and product liability insurance. Wind load class per EN 12424 and thermal data are confirmed per project. RAX can also support AS/NZS 4505 (Australia) and UL (North America) counterpart test data.

What is the lead time and warranty?

Sample 7–15 days; standard container 12–20 days; custom first order 20–35 days. Door body 2-year warranty, operator/motor 3 years (servo 5 years), with spare parts dispatched by DHL/FedEx within 5–7 days.

Or email info@raxdoor.com