{"id":541,"date":"2026-08-03T15:43:42","date_gmt":"2026-08-03T15:43:42","guid":{"rendered":"https:\/\/www.raxdoors.com\/products\/sectional-doors\/fire-resistant-sectional-door\/"},"modified":"2026-09-12T21:26:23","modified_gmt":"2026-09-12T13:26:23","slug":"fire-resistant-sectional-door","status":"publish","type":"page","link":"https:\/\/www.raxdoors.com\/pt\/sectional-doors\/fire-resistant-sectional-door\/","title":{"rendered":"Porta seccional resistente ao fogo"},"content":{"rendered":"\n<!-- deliverable: wp-fragment -->\n<!--\n================================================================================\nRAX DOOR TECHNOLOGY \u2014 Fire Resistant Sectional Door (Sectional Doors)\nEnriched with researched technical data. main.css classes only.\n================================================================================\n-->\n\n<div class=\"page-shell\">\n\n  <section class=\"section-dark page-hero section\">\n    <div class=\"container-xl\">\n      <nav class=\"page-breadcrumbs\" aria-label=\"Breadcrumb\">\n        <a href=\"https:\/\/www.raxdoors.com\/\">Home<\/a>\n        <span class=\"page-breadcrumbs__separator\">\/<\/span>\n        <a href=\"https:\/\/www.raxdoors.com\/products\/\">Products<\/a>\n        <span class=\"page-breadcrumbs__separator\">\/<\/span>\n        <a href=\"\/sectional-doors\/\">Sectional Doors<\/a>\n        <span class=\"page-breadcrumbs__separator\">\/<\/span>\n        <span>Fire Resistant Sectional Door<\/span>\n      <\/nav>\n      <div class=\"page-hero__layout\">\n        <div class=\"page-section__copy\">\n          <span class=\"eyebrow\">Sectional Doors \u00b7 Manufacturer since 1999<\/span>\n          <h1>Fire Resistant Sectional Door<\/h1>\n          <div class=\"btn-group\">\n            <span class=\"pill\">EI30\/EI60\/EI90\/EI120<\/span>\n            <span class=\"pill\">CE \u00b7 EN 16034<\/span>\n            <span class=\"pill\">Full technical drawings<\/span>\n          <\/div>\n          <div class=\"page-actions\">\n            <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n            <a class=\"btn btn-outline\" href=\"#specs\">View Specifications<\/a>\n          <\/div>\n        <\/div>\n        <div class=\"page-hero__media\">\n          <img decoding=\"async\" class=\"rax-hero-img\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/Compact-Sectional-Door-Drawing.jpg\" alt=\"Fire Resistant Sectional Door \u2014 RAX Door Technology\">\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">01 \u00b7 Overview<\/span>\n        <h2>Fire Compartmentalization for Industrial Facilities<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <p>Fire resistant sectional doors are engineered to maintain fire compartmentalization in industrial and commercial buildings. Unlike standard sectional doors that use PU foam cores, fire resistant doors use mineral wool\/rock wool cores (density 145\u2013180 kg\/m\u00b3) with thicker galvanized steel skins (0.7\u20130.9 mm vs. 0.3\u20130.6 mm standard) to withstand extreme temperatures. Fire resistance ratings range from EI30 (30 minutes) to EI120 (120 minutes), where E = Integrity (prevents flame and hot gas penetration) and I = Insulation (prevents heat transmission).<\/p>\n        <p>RAX manufactures fire resistant sectional doors with 53 mm thick panels containing rock wool cores, galvanized steel reinforcement ribs, and graphite intumescent seals that expand 25\u00d7 at 150\u00b0C to block smoke propagation. Low thermal conductivity steel frames (1.5 mm thickness) reduce heat transfer. Doors are certified per EN 16034 (fire and smoke door product standard) and tested per EN 1634-1 (fire resistance test method). CE marking mandatory for EU\/UK export.<\/p>\n        <p>Fire resistant doors are essential for firewall openings, fire compartment boundaries, escape routes, technical rooms (electrical\/mechanical), hospitals, schools, high-rise residential buildings, and industrial facilities requiring fire separation. Note: fire doors are certified as complete assemblies \u2014 any component substitution (hardware, seals, glass) may void certification.<\/p>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">02 \u00b7 Key Features<\/span>\n        <h2>Engineered for Fire Safety and Compliance<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"grid-3\">\n          <div class=\"card\"><h3>Fire Resistance Ratings<\/h3><p>EI30 (30 min), EI60 (60 min), EI90 (90 min), EI120 (120 min). E = Integrity (blocks flame\/hot gas), I = Insulation (blocks heat transfer). Rating selection depends on building code and firewall rating requirements.<\/p><\/div>\n          <div class=\"card\"><h3>Rock Wool Core<\/h3><p>Mineral wool\/rock wool core density 145\u2013180 kg\/m\u00b3 (vs. PU foam ~42\u201348 kg\/m\u00b3 in standard doors). Non-combustible, maintains structural integrity at extreme temperatures. Panel thickness 53 mm.<\/p><\/div>\n          <div class=\"card\"><h3>Intumescent Seals<\/h3><p>Graphite intumescent gaskets (15\u00d72 mm) expand 25\u00d7 at 150\u00b0C to seal gaps and prevent smoke propagation. Smoke seal (Sa designation) critical for escape routes and occupied spaces.<\/p><\/div>\n          <div class=\"card\"><h3>Thick Steel Skins<\/h3><p>0.7\u20130.9 mm galvanized steel skins (vs. 0.3\u20130.6 mm standard). Thicker steel withstands extreme heat without deformation. Galvanized coating prevents corrosion in humid environments.<\/p><\/div>\n          <div class=\"card\"><h3>Certified Assembly<\/h3><p>Doors certified as complete assemblies per EN 16034 + EN 1634-1. All components (hardware, seals, glass, dimensions) must match tested configuration. Component substitution voids certification.<\/p><\/div>\n          <div class=\"card\"><h3>Size Range<\/h3><p>Width 1,000\u20138,000 mm, height 1,500\u201310,000 mm. Track thickness 2 mm. Operating speed 10\u201315 m\/min. Motor power 0.75\u20131.5 kW. Lift configurations: standard, high lift, vertical lift.<\/p><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section id=\"specs\" class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">03 \u00b7 Technical Data<\/span>\n        <h2>Technical Specifications<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"data-table-wrap\">\n          <table class=\"data-table\">\n            <tr><td class=\"row-label\">Product<\/td><td>Fire Resistant Sectional Door (also: Fire Rated Sectional Door \u00b7 EI-Rated Sectional Door)<\/td><\/tr>\n            <tr><td class=\"row-label\">Category<\/td><td>Sectional Doors<\/td><\/tr>\n            <tr><td class=\"row-label\">Fire ratings<\/td><td>EI30 \/ EI60 \/ EI90 \/ EI120 (30\/60\/90\/120 minutes integrity + insulation)<\/td><\/tr>\n            <tr><td class=\"row-label\">Panel construction<\/td><td>Galvanized steel double-skin with rock wool core<\/td><\/tr>\n            <tr><td class=\"row-label\">Panel thickness<\/td><td>53 mm<\/td><\/tr>\n            <tr><td class=\"row-label\">Steel skin thickness<\/td><td>0.7\u20130.9 mm (fire rated); 0.3\u20130.6 mm (standard)<\/td><\/tr>\n            <tr><td class=\"row-label\">Core material<\/td><td>Rock wool\/mineral wool, density 145\u2013180 kg\/m\u00b3<\/td><\/tr>\n            <tr><td class=\"row-label\">Reinforcement<\/td><td>Galvanized steel reinforcement ribs<\/td><\/tr>\n            <tr><td class=\"row-label\">Intumescent seals<\/td><td>Graphite gaskets 15\u00d72 mm, expand 25\u00d7 at 150\u00b0C<\/td><\/tr>\n            <tr><td class=\"row-label\">Frame<\/td><td>Low thermal conductivity steel, 1.5 mm thickness<\/td><\/tr>\n            <tr><td class=\"row-label\">Width range<\/td><td>1,000\u20138,000 mm<\/td><\/tr>\n            <tr><td class=\"row-label\">Height range<\/td><td>1,500\u201310,000 mm<\/td><\/tr>\n            <tr><td class=\"row-label\">Track thickness<\/td><td>2 mm<\/td><\/tr>\n            <tr><td class=\"row-label\">Operating speed<\/td><td>10\u201315 m\/min<\/td><\/tr>\n            <tr><td class=\"row-label\">Motor power<\/td><td>0.75\u20131.5 kW<\/td><\/tr>\n            <tr><td class=\"row-label\">Certification<\/td><td>EN 16034 (fire\/smoke door product standard); EN 1634-1 (fire resistance test); EN 13241 (general door standard); CE marking<\/td><\/tr>\n            <tr><td class=\"row-label\">Order<\/td><td>Custom engineered to your fire rating and opening size specification<\/td><\/tr>\n          <\/table>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;text-align:center;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">04 \u00b7 Applications<\/span>\n        <h2>Where Fire Resistant Doors Are Required<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"grid-3\">\n          <div class=\"card\"><h3>Firewall Openings<\/h3><p>Maintain firewall integrity where vehicle\/pedestrian access is required. Fire doors must match or exceed the firewall rating (e.g., 2-hour firewall requires EI120 door). Critical for industrial facilities with fire compartment requirements.<\/p><\/div>\n          <div class=\"card\"><h3>Fire Compartment Boundaries<\/h3><p>Separate industrial areas and rooms into fire compartments to limit fire spread. Required by building codes for large facilities. Fire doors maintain compartmentalization while allowing necessary access.<\/p><\/div>\n          <div class=\"card\"><h3>Escape Routes<\/h3><p>Protect evacuation paths with smoke-sealed fire doors (Sa designation). Intumescent seals expand to block smoke propagation. Critical for life safety in hospitals, schools, and high-rise buildings.<\/p><\/div>\n          <div class=\"card\"><h3>Technical Rooms<\/h3><p>Electrical rooms, mechanical rooms, and boiler rooms with elevated fire risk. Fire doors prevent fire from spreading to adjacent occupied spaces. EI60 minimum typically required.<\/p><\/div>\n          <div class=\"card\"><h3>Hospitals &amp; Schools<\/h3><p>High-occupancy buildings require strict fire separation. Fire doors protect evacuation routes and limit fire spread. EI60\u2013EI120 ratings typical for healthcare and educational facilities.<\/p><\/div>\n          <div class=\"card\"><h3>Warehouses &amp; Industrial<\/h3><p>Storage areas with fire load (flammable materials) require fire compartmentalization. Fire doors separate high-risk zones from general storage. EI30\u2013EI60 typical for warehouse applications.<\/p><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">05 \u00b7 Fire Resistant vs. Standard<\/span>\n        <h2>Understanding the Differences<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"data-table-wrap\">\n          <table class=\"data-table\">\n            <tr><th>Feature<\/th><th>Fire Resistant Door<\/th><th>Standard Door<\/th><\/tr>\n            <tr><td class=\"row-label\">Core material<\/td><td>Rock wool (145\u2013180 kg\/m\u00b3)<\/td><td>PU foam (~42\u201348 kg\/m\u00b3)<\/td><\/tr>\n            <tr><td class=\"row-label\">Steel skin thickness<\/td><td>0.7\u20130.9 mm<\/td><td>0.3\u20130.6 mm<\/td><\/tr>\n            <tr><td class=\"row-label\">Panel thickness<\/td><td>53 mm<\/td><td>40\u201350 mm<\/td><\/tr>\n            <tr><td class=\"row-label\">Seals<\/td><td>Intumescent (expand at 150\u00b0C)<\/td><td>EPDM rubber<\/td><\/tr>\n            <tr><td class=\"row-label\">Fire rating<\/td><td>EI30\u2013EI120<\/td><td>None<\/td><\/tr>\n            <tr><td class=\"row-label\">Certification<\/td><td>EN 16034 + EN 1634-1 + CE<\/td><td>EN 13241 + CE<\/td><\/tr>\n            <tr><td class=\"row-label\">Component substitution<\/td><td>Not allowed (voids certification)<\/td><td>Allowed<\/td><\/tr>\n            <tr><td class=\"row-label\">Cost<\/td><td>Higher (specialized materials + testing)<\/td><td>Standard pricing<\/td><\/tr>\n            <tr><td class=\"row-label\">Best for<\/td><td>Firewalls, escape routes, technical rooms<\/td><td>General access, non-fire-rated openings<\/td><\/tr>\n          <\/table>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">06 \u00b7 Customization<\/span>\n        <h2>OEM \/ ODM &amp; Customization<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <p>RAX supports full private-label production of the Fire Resistant Sectional Door: custom fire rating (EI30\u2013EI120), RAL frame colors, operator matching, packaging printing and installation-manual translation (EN\/ES\/FR\/AR\/RU). Start with an OEM sample and scale to container-load branded production. Custom molds and tooling records are archived for up to 5 years \u2014 no extra tooling fee on repeat orders, all under strict NDA. Note: fire door certifications are size-specific \u2014 custom sizes outside tested range require additional testing.<\/p>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">07 \u00b7 Compliance<\/span>\n        <h2>Applicable Standards<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"grid-3\">\n          <div class=\"card\"><h3>EN 16034<\/h3><p>EU product standard for fire and smoke doors. Covers fire resistance, smoke control, and durability. Requires Declaration of Performance (DoP) under CPR 305\/2011. CE marking mandatory for fire doors in EU\/UK markets.<\/p><\/div>\n          <div class=\"card\"><h3>EN 1634-1<\/h3><p>Fire resistance test method for doors and shutters. Tests integrity (E) and insulation (I) under standard fire curve. Determines EI rating (30\/60\/90\/120 minutes). Tests conducted by accredited laboratories.<\/p><\/div>\n          <div class=\"card\"><h3>EN 13241:2003+A2:2016<\/h3><p>General product standard for industrial, commercial, and garage doors. Fire doors must comply with both EN 16034 (fire-specific) and EN 13241 (general requirements).<\/p><\/div>\n          <div class=\"card\"><h3>EN 14600<\/h3><p>Durability certification for fire doors. C5 rating indicates highest durability class for high-frequency use. Required for doors in busy industrial facilities.<\/p><\/div>\n          <div class=\"card\"><h3>EN 13501-2<\/h3><p>EU classification standard for fire performance of construction products. Defines EI rating syntax and additional classifications (durability, smoke control).<\/p><\/div>\n          <div class=\"card\"><h3>CE Marking<\/h3><p>Mandatory for fire doors exported to EU\/UK markets. Indicates compliance with EN 16034 and CPR 305\/2011. RAX provides CE technical file, Declaration of Performance, and fire test certificates with every shipment.<\/p><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">08 \u00b7 Why RAX<\/span>\n        <h2>Why Buyers Choose RAX for Fire Resistant Doors<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <ul>\n          <li><strong>27-year zero-leak track record<\/strong> \u2014 5,000+ overseas projects delivered since 1999, with no leakage complaints on door bodies<\/li>\n          <li><strong>Full fire rating range<\/strong> \u2014 EI30, EI60, EI90, EI120 to match any firewall rating requirement<\/li>\n          <li><strong>Certified assemblies<\/strong> \u2014 EN 16034 + EN 1634-1 tested, CE marked, complete documentation package<\/li>\n          <li><strong>Intumescent smoke seals<\/strong> \u2014 graphite gaskets expand 25\u00d7 at 150\u00b0C to block smoke propagation<\/li>\n          <li><strong>Rock wool cores<\/strong> \u2014 non-combustible, density 145\u2013180 kg\/m\u00b3, maintains integrity at extreme temperatures<\/li>\n          <li><strong>Deep customization<\/strong> \u2014 every door engineered to your exact size, specification, and application requirements<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-soft section\">\n    <div class=\"container-xl\">\n      <div class=\"faq-split\">\n        <aside class=\"faq-split__left\" aria-label=\"FAQ overview\">\n          <span class=\"faq-split__eyebrow\">09 \u00b7 Buyer FAQ<\/span>\n          <h2 class=\"faq-split__title\">Fire resistant sectional door questions<span class=\"accent\">,<\/span> answered<span class=\"accent\">.<\/span><\/h2>\n          <p class=\"faq-split__lead\">Technical answers on fire ratings, certification, components, and compliance.<\/p>\n          <a class=\"faq-split__cta\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a quote\n            <svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\">\n              <line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"><\/line>\n              <polyline points=\"12 5 19 12 12 19\"><\/polyline>\n            <\/svg>\n          <\/a>\n        <\/aside>\n        <div class=\"faq-split__right\">\n          <div class=\"faq-stack\">\n            <details><summary>What do EI30, EI60, EI90, EI120 mean?<\/summary><div class=\"faq-stack__answer\"><p>EI ratings indicate fire resistance duration in minutes. E = Integrity (prevents flame and hot gas penetration), I = Insulation (prevents heat transmission). EI30 = 30 minutes, EI60 = 60 minutes, EI90 = 90 minutes, EI120 = 120 minutes. Rating selection depends on building code and firewall rating requirements.<\/p><\/div><\/details>\n            <details><summary>What is the difference between fire resistant and standard sectional doors?<\/summary><div class=\"faq-stack__answer\"><p>Fire resistant doors use rock wool cores (density 145\u2013180 kg\/m\u00b3) with thicker steel skins (0.7\u20130.9 mm vs. 0.3\u20130.6 mm standard). Intumescent seals expand at 150\u00b0C to block smoke. Standard doors use PU foam cores and EPDM seals. Fire doors are certified assemblies \u2014 component substitution voids certification.<\/p><\/div><\/details>\n            <details><summary>What certifications are required for fire doors?<\/summary><div class=\"faq-stack__answer\"><p>EU\/UK markets require EN 16034 (fire\/smoke door product standard) + EN 1634-1 (fire resistance test) + CE marking. Fire doors must have Declaration of Performance (DoP) under CPR 305\/2011. RAX provides complete certification package with every shipment.<\/p><\/div><\/details>\n            <details><summary>Can components be substituted on fire doors?<\/summary><div class=\"faq-stack__answer\"><p>No. Fire doors are certified as complete assemblies. Any component substitution (hardware, seals, glass, dimensions) may void certification. Technical drawings must list exact components used in testing. Unauthorized changes invalidate the fire rating.<\/p><\/div><\/details>\n            <details><summary>What applications require fire resistant doors?<\/summary><div class=\"faq-stack__answer\"><p>Firewall openings, fire compartment boundaries, escape routes, technical rooms (electrical\/mechanical), hospitals, schools, high-rise residential buildings, and industrial facilities requiring fire separation. Building codes specify where fire doors are mandatory.<\/p><\/div><\/details>\n            <details><summary>Do you provide installation?<\/summary><div class=\"faq-stack__answer\"><p>No \u2014 RAX is a pure manufacturer. Doors ship with English installation manuals, wiring diagrams, and remote support. We recommend using a qualified local installer who can verify structural capacity and proper seal installation.<\/p><\/div><\/details>\n            <details><summary>What is the lead time and warranty?<\/summary><div class=\"faq-stack__answer\"><p>Standard configurations: 12\u201320 days. Custom first order: 20\u201335 days. Repeat orders: 15\u201320 days. Warranty: panels 10 years, automation components 5 years. Warranty replacement parts shipped via DHL\/FedEx in 5\u20137 days.<\/p><\/div><\/details>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"center-stack\">\n        <span class=\"eyebrow\">10 \u00b7 Get Started<\/span>\n        <h2>Get Your Fire Resistant Sectional Door Proposal<\/h2>\n        <p class=\"lead\">Send your opening size, required fire rating (EI30\/EI60\/EI90\/EI120), and building code requirements \u2014 we reply with a specification, certification documentation, lead time, and quote.<\/p>\n        <div class=\"btn-group\">\n          <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n<\/div>\n\n<script type=\"application\/ld+json\">{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Product\",\n      \"name\": \"Fire Resistant Sectional Door\",\n      \"category\": \"Sectional Doors\",\n      \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"RAX Door Technology\"\n      },\n      \"manufacturer\": {\n        \"@type\": \"Organization\",\n        \"name\": \"RAX Door Technology Co., Ltd.\",\n        \"url\": \"https:\/\/www.raxdoors.com\/#organization\"\n      },\n      \"description\": \"Custom Fire Resistant Sectional Door manufactured to order by RAX Door Technology. EI30\/EI60\/EI90\/EI120 ratings, rock wool core, intumescent seals. EN 16034 + EN 1634-1 certified, CE marked. Manufacturer since 1999.\",\n      \"offers\": {\n        \"@type\": \"Offer\",\n        \"availability\": \"https:\/\/schema.org\/InStock\",\n        \"priceCurrency\": \"USD\",\n        \"price\": \"1300\",\n        \"description\": \"Made to order \u2014 request a quote\",\n        \"url\": \"https:\/\/www.raxdoors.com\/sectional-doors\/fire-resistant-sectional-door\/\",\n        \"priceValidUntil\": \"2027-12-31\",\n        \"validFrom\": \"2026-09-12\",\n        \"hasMerchantReturnPolicy\": {\n          \"@type\": \"MerchantReturnPolicy\",\n          \"applicableCountry\": \"US\",\n          \"returnPolicyCategory\": \"https:\/\/schema.org\/MerchantReturnNotPermitted\",\n          \"returnMethod\": \"https:\/\/schema.org\/ReturnByMail\",\n          \"returnFees\": \"https:\/\/schema.org\/NonReturnableFee\"\n        },\n        \"shippingDetails\": {\n          \"@type\": \"OfferShippingDetails\",\n          \"shippingRate\": {\n            \"@type\": \"MonetaryAmount\",\n            \"value\": \"0\",\n            \"currency\": \"USD\"\n          },\n          \"shippingDestination\": {\n            \"@type\": \"DefinedRegion\",\n            \"addressCountry\": \"US\"\n          },\n          \"deliveryTime\": {\n            \"@type\": \"ShippingDeliveryTime\",\n            \"handlingTime\": {\n              \"@type\": \"QuantitativeValue\",\n              \"minValue\": 15,\n              \"maxValue\": 45,\n              \"unitCode\": \"DAY\"\n            },\n            \"transitTime\": {\n              \"@type\": \"QuantitativeValue\",\n              \"minValue\": 7,\n              \"maxValue\": 30,\n              \"unitCode\": \"DAY\"\n            }\n          }\n        }\n      }\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"itemListElement\": [\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 1,\n          \"name\": \"Home\",\n          \"item\": \"https:\/\/www.raxdoors.com\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 2,\n          \"name\": \"Products\",\n          \"item\": \"https:\/\/www.raxdoors.com\/products\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 3,\n          \"name\": \"Sectional Doors\",\n          \"item\": \"\/sectional-doors\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 4,\n          \"name\": \"Fire Resistant Sectional Door\",\n          \"item\": \"\/sectional-doors\/fire-resistant-sectional-door\/\"\n        }\n      ]\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What do EI30, EI60, EI90, EI120 mean?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"EI ratings indicate fire resistance duration in minutes. E = Integrity (prevents flame\/hot gas), I = Insulation (prevents heat transfer). EI30 = 30 min, EI60 = 60 min, EI90 = 90 min, EI120 = 120 min.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is the difference between fire resistant and standard sectional doors?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Fire resistant doors use rock wool cores (145\u2013180 kg\/m\u00b3) with thicker steel skins (0.7\u20130.9 mm). Intumescent seals expand at 150\u00b0C to block smoke. Standard doors use PU foam cores. Fire doors are certified assemblies \u2014 component substitution voids certification.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What certifications are required for fire doors?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"EU\/UK markets require EN 16034 + EN 1634-1 + CE marking. Fire doors must have Declaration of Performance under CPR 305\/2011. RAX provides complete certification package.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can components be substituted on fire doors?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"No. Fire doors are certified as complete assemblies. Any component substitution may void certification. Technical drawings must list exact components used in testing.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What applications require fire resistant doors?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Firewall openings, fire compartment boundaries, escape routes, technical rooms, hospitals, schools, high-rise buildings, and industrial facilities requiring fire separation.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Do you provide installation?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"No \u2014 RAX is a pure manufacturer. Doors ship with English installation manuals, wiring diagrams, and remote support.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is the lead time and warranty?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Standard configurations: 12\u201320 days. Custom first order: 20\u201335 days. Repeat orders: 15\u201320 days. Warranty: panels 10 years, automation 5 years.\"\n          }\n        }\n      ]\n    }\n  ]\n}<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>In\u00edcio \/ Produtos \/ Portas Seccionais \/ Porta Seccional Resistente ao Fogo Portas Seccionais \u00b7 Fabricante desde 1999 Porta Seccional Resistente ao Fogo EI30\/EI60\/EI90\/EI120 CE \u00b7 EN 16034 Desenhos t\u00e9cnicos completos Pe\u00e7a um or\u00e7amento gratuito Ver especifica\u00e7\u00f5es 01 \u00b7 Vis\u00e3o geral Compartimenta\u00e7\u00e3o de inc\u00eandio para instala\u00e7\u00f5es industriais As portas seccionais resistentes ao fogo s\u00e3o projetadas para manter a compartimenta\u00e7\u00e3o contra inc\u00eandio em ambientes industriais \u2026 <a title=\"Porta seccional resistente ao fogo\" class=\"read-more\" href=\"https:\/\/www.raxdoors.com\/pt\/sectional-doors\/fire-resistant-sectional-door\/\" aria-label=\"Leia mais sobre Porta Seccional Resistente ao Fogo\">Ler mais<\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":14,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-541","page","type-page","status-publish"],"_links":{"self":[{"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/pages\/541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/comments?post=541"}],"version-history":[{"count":9,"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/pages\/541\/revisions"}],"predecessor-version":[{"id":4133,"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/pages\/541\/revisions\/4133"}],"up":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/pages\/14"}],"wp:attachment":[{"href":"https:\/\/www.raxdoors.com\/pt\/wp-json\/wp\/v2\/media?parent=541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}