{"id":6612,"date":"2026-10-23T10:26:50","date_gmt":"2026-10-23T02:26:50","guid":{"rendered":"https:\/\/www.raxdoors.com\/blog\/jis-a-4722-automatic-door-safety\/"},"modified":"2026-10-23T10:26:50","modified_gmt":"2026-10-23T02:26:50","slug":"jis-a-4722-automatic-door-safety","status":"publish","type":"post","link":"https:\/\/www.raxdoors.com\/fr\/blog\/jis-a-4722-automatic-door-safety\/","title":{"rendered":"JIS A 4722 : comment le Japon \u00e9value la s\u00e9curit\u00e9 des portes automatiques"},"content":{"rendered":"<p><!-- wc=1746 --><\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Automatic door tenders are usually settled on three visible grounds: price, brand name, and panel finish. Safety performance rarely enters the comparison, because buyers have no verifiable yardstick to apply. The one Japanese standard that defines that yardstick barely surfaces in English. Its only in-depth explainer spends half its length promoting its own sensors, and the real figures sit locked inside Japanese pages.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">In our practice, verification begins with the paperwork attached to the door. Every door we ship leaves the factory with a signed inspection report recording measured opening speed, noise, and insulation resistance. That is the same handover logic JIS A 4722 demands when a finished installation is checked and accepted. Safety that cannot be produced as a document at handover does not exist for the buyer, and Japan&#8217;s automatic door standard is arranged around that test.<\/p>\n<h2 id=\"what-the-jis-a-4722-standard-actually-covers\">What the JIS A 4722 Standard Actually Covers<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">JIS A 4722 is Japan&#8217;s national safety standard for powered automatic door sets used by pedestrians. It was first published in 2017 and revised in 2022. The revision added requirements for automatic doors on accessible toilet compartments and introduced a recommendation for finger-protection buffers in places where children gather.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Scope is the second thing worth reading closely. The standard follows a powered pedestrian door set across its whole life: product design, technical specifications, installation, completion inspection, and the maintenance checks that continue through years of service. The supplier performs the completion inspection and hands the results to the building owner and the building manager.<\/p>\n<figure style=\"margin:26px 0;\">\n<img src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-sliding-cleanroom-door-operator-header.webp\" alt=\"automatic sliding door set with glazed leaf and operator at a commercial entrance\" width=\"1200\" height=\"799\" class=\"wp-image-3233\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:6px;display:block;\" srcset=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-sliding-cleanroom-door-operator-header.webp 1200w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-sliding-cleanroom-door-operator-header-300x200.webp 300w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-sliding-cleanroom-door-operator-header-1024x682.webp 1024w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-sliding-cleanroom-door-operator-header-768x511.webp 768w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-sliding-cleanroom-door-operator-header-18x12.webp 18w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption style=\"margin:10px 0 0;font-size:.88rem;line-height:1.55;color:#5f5e5a;text-align:center;font-style:italic;\">A powered sliding door set, where operator, leaf, and sensors form the unit the standard evaluates.<\/figcaption><\/figure>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">For a buyer, compliance lives in documents as much as in hardware. Ask what the completion inspection measured and who received the record. A supplier who answers both quickly has done most of the work.<\/p>\n<h2 id=\"three-parties-hold-the-safety-duty\">Three Parties Hold the Safety Duty<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Safety duty under the standard is split among three parties, and each holds a piece the others cannot cover. The supplier manufactures, sells, and installs the door set with compliant devices, designing countermeasures around pedestrian behavior at doorways. Building designers and owners carry the planning stage, where traffic volume and user groups are fixed into the specification. Decisions skipped there cannot be repaired by hardware later.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">The building manager holds the longest duty. Daily checks continue for the life of the installation, professional maintenance is arranged with qualified personnel, and the results are kept as records. When a maintenance result fails to meet the standard&#8217;s requirements, the manager must take appropriate and necessary measures.<\/p>\n<figure style=\"margin:26px 0;\">\n<img src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/automatic-hospital-doors-types-stock-2.webp\" alt=\"pedestrians passing automatic doors in a facility corridor\" width=\"1200\" height=\"675\" class=\"wp-image-3233\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:6px;display:block;\"><figcaption style=\"margin:10px 0 0;font-size:.88rem;line-height:1.55;color:#5f5e5a;text-align:center;font-style:italic;\">Daily traffic at a facility entrance, where the manager&#8217;s checks continue across the door&#8217;s life.<\/figcaption><\/figure>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Buyers can use this split directly during procurement. Ask which party performs each duty in your project, and get the answer in writing. A door set with no named maintenance holder is unfinished engineering.<\/p>\n<h2 id=\"opening-phase-hazards-and-the-fix-options\">Opening-Phase Hazards and the Fix Options<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Opening is where the standard concentrates its hardest numbers. On the door-pocket side of a sliding leaf, the hazards are squeezing and collision against the parked door, plus fingers drawn into the gap as the leaf starts to move. The standard answers with a menu of countermeasures and lets a design satisfy it by choosing one.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">A guard screen over the pocket area is one option, with gaps no wider than 8mm or held between 25mm and 100mm. Coverage must reach 2500mm above the floor, and removal is possible only with tools. A protective fence stands at least 900mm high, its bottom gap should stay within 100mm, and its top rail withstands 490N per 1000mm of width without damage. Safety distance, door speed control with low-energy operation, and an opening protection sensor complete the menu.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Finger entrapment gets its own rules. The facing surfaces of the door leaf and the adjacent fixed panel must carry no ribbed or grille-like projections. Where the gap between stile and glass exceeds 8mm, the distance from the leading stile to the fixed member must be at least 25mm. The 2022 revision recommends finger buffers at the door pocket and stile where children use the door heavily.<\/p>\n<h2 id=\"closing-phase-sensors-and-knowing-act-devices\">Closing-Phase Sensors and Knowing-Act Devices<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Closing flips the hazard to the open side, where a person or a trolley stands in the moving leaf&#8217;s path. Protection there means a reflective optical sensor or an auxiliary photoelectric sensor, one of the two, creating a protective zone across the opening. Door speed control with low-energy operation can substitute where the design suits it. Dash-through protection relies on the sensor&#8217;s starting detection range, alone or with a tactile switch.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Touch switches follow a universal-design figure: 950\u00b150mm from the floor to the center of the switch. The band accommodates wheelchair users and older pedestrians without a separate installation. Knowing-act devices such as card readers and push buttons belong to the same family, opening the door in response to a deliberate action.<\/p>\n<figure style=\"margin:26px 0;\">\n<img src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/commercial-access-control-keypad-card-reader.webp\" alt=\"wall-mounted card reader controlling an automatic door entrance\" width=\"1200\" height=\"799\" class=\"wp-image-3233\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:6px;display:block;\"><figcaption style=\"margin:10px 0 0;font-size:.88rem;line-height:1.55;color:#5f5e5a;text-align:center;font-style:italic;\">A card reader acting as a knowing-act device, opening the door in response to a deliberate user action.<\/figcaption><\/figure>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Sensor coverage is only as reliable as the controller supervising it. A controller that self-checks its sensors detects a drifting or failing unit before the failure reaches a pedestrian. Our guide to the <a href=\"https:\/\/www.raxdoors.com\/blog\/high-speed-door-control-panel-guide\/\">high speed door control panel<\/a> explains how that self-check logic is built.<\/p>\n<h2 id=\"materials-glass-and-signage-rules\">Materials, Glass and Signage Rules<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Some requirements apply no matter which countermeasures a design selects. Door leaves and frames must carry no sharp edges, and glass must not form sharp fragments if it breaks. Signage is mandatory in four respects: an automatic-door display, an indication of opening direction, caution guidance against standing still or dashing through, and a pull-in warning at the pocket side.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Records and signage extend the building manager&#8217;s duty rather than ending at delivery. The maintenance record and the warning signs are the two things a visitor actually sees of the whole safety system. Treat both as deliverables on the order, not as site extras.<\/p>\n<div class=\"cta-box\" style=\"background:#0f2744;color:#ffffff;padding:24px 28px;border-radius:6px;margin:32px 0;text-align:center;\">\n<h3 class=\"cta-title\" style=\"margin-top:0;font-size:20px;font-weight:700;\">Who Checks the Safety Files on Your Automatic Door Order?<\/h3>\n<p style=\"color:#e2e8f0;margin-bottom:18px;font-size:15px;\">Specify the operator, sensors, and handover documents together, and our engineering team matches powered door hardware to the safety duties your project assigns.<\/p>\n<p><a href=\"https:\/\/www.raxdoors.com\/door-operators\/\" style=\"display:inline-block;background:#007bff;color:#ffffff;padding:12px 24px;border-radius:4px;font-weight:700;text-decoration:none;\">Review Door Operator Options<\/a> <\/p>\n<\/p><\/div>\n<h2 id=\"how-the-us-framework-handles-the-same-risks\">How the US Framework Handles the Same Risks<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">The American framework answers the same hazards with quantified performance thresholds instead of a countermeasure menu. Under <a href=\"https:\/\/buildershardware.com\/ANSI-BHMA-Standards\/Hardware-Highlights\/A15610-2017-Power-Operated-Pedestrian-Doors\" target=\"_blank\" rel=\"noopener\">ANSI\/BHMA A156.10<\/a>, a swinging powered door must take at least 1.5 seconds to open to 80 degrees. The force able to stop it within the final 10 degrees must not exceed 30 lbf (133 N). A knowing-act hold-open runs at least 5 seconds after release, with 1 second added per foot beyond 12 feet.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Accessibility sits in a separate instrument. The <a href=\"https:\/\/www.ada.gov\/law-and-regs\/design-standards\/2010-stds\/\" target=\"_blank\" rel=\"noopener\">2010 ADA Standards<\/a> treat a full-power automatic door as part of an accessible route, with the 32-inch minimum clear width measured with the door in the full open position. A leaf stopped partway steals width exactly where the standard checks it.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">The two systems reward different verification habits. JIS A 4722 hands you a countermeasure matrix per hazard phase plus a three-party duty chain, so you verify by matching measures to traffic and asking for the documents. A156.10 hands you thresholds, so you verify with a stopwatch, a force gauge, and a tape. ADA adds the accessibility width check on top.<\/p>\n<h2 id=\"a-selection-checklist-for-specifiers\">A Selection Checklist for Specifiers<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">Verification is easier with a fixed list. The checklist below is what we keep beside the drawing set when a pedestrian automatic door order under JIS A 4722 is reviewed. It maps one to one onto the duties described above, and each row ends in a document or a measured value.<\/p>\n<table style=\"display: table !important; width: 100% !important; border-collapse: collapse; margin-bottom: 28px;\">\n<thead>\n<tr>\n<th style=\"text-align: left; padding: 12px 14px; background: #1f3a5f; color: #ffffff; font-weight: 600;\">Check item<\/th>\n<th style=\"text-align: left; padding: 12px 14px; background: #1f3a5f; color: #ffffff; font-weight: 600;\">What to request<\/th>\n<th style=\"text-align: left; padding: 12px 14px; background: #1f3a5f; color: #ffffff; font-weight: 600;\">What a pass looks like<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Compliance declaration<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Certificates for operator and sensors<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Standard scope named for the full door set<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Opening-phase measures<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Countermeasure chosen for the pocket side<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Guard screen, fence, distance, speed control, or sensor<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Closing-phase protection<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Sensor type and coverage drawing<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Reflective or auxiliary photoelectric zone across the opening<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Completion inspection<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Signed completion check results<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Measured values delivered to owner and manager<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Maintenance plan<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Named duty holder and check schedule<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Manager&#8217;s duty and records confirmed in writing<\/td>\n<\/tr>\n<tr>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Signage and warnings<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Required signs supplied with the set<\/td>\n<td style=\"padding: 12px 14px; border-bottom: 1px solid #e5e5e5; vertical-align: top;\">Automatic display, direction, caution, and pull-in warning<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">One boundary should be drawn before the list is applied. Pedestrian automatic doors and industrial door operators are separate product domains, and our industrial operators follow EN 12453 with CE certification under EN 13241. For gate and warehouse openings, this article on <a href=\"https:\/\/www.raxdoors.com\/blog\/industrial-sliding-door-opener\/\">how an industrial sliding door opener works<\/a> covers that regime instead.<\/p>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">For pedestrian entrances, matching the operator to the sensor set and the handover documents matters more than any brochure figure. Our <a href=\"https:\/\/www.raxdoors.com\/door-operators\/sliding-door-opener\/\">automatic sliding door opener<\/a> range lists 16 models, backed by a 3-year operator warranty, 5 years on servo motors, and 2 years on the door panel. The delivery pack follows the same logic: measured values, signed.<\/p>\n<h2 id=\"frequently-asked-questions\">Frequently Asked Questions<\/h2>\n<p style=\"line-height: 1.8; margin-bottom: 28px;\">These are the questions procurement teams raise most often when this standard appears in a specification. The answers stay within the standard itself. Our own practice is marked where it adds context.<\/p>\n<div class=\"faq-card\" style=\"background:#f9f9f9;border:1px solid #eee;border-radius:4px;padding:18px 22px;margin:14px 0;\">\n<h3>Is JIS A 4722 mandatory in Japan?<\/h3>\n<p style=\"margin:0;line-height:1.7;\">JIS A 4722 is Japan&#8217;s national standard for pedestrian automatic door sets. Its force in projects comes through the three-party duty structure it defines, which assigns checks, records, and follow-up measures to supplier, building owner, and manager.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9;border:1px solid #eee;border-radius:4px;padding:18px 22px;margin:14px 0;\">\n<h3>What changed in the 2022 revision?<\/h3>\n<p style=\"margin:0;line-height:1.7;\">The 2022 revision added requirements for automatic doors on accessible toilet compartments and recommended finger-protection buffers where children gather, extending the countermeasure framework first published in 2017.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9;border:1px solid #eee;border-radius:4px;padding:18px 22px;margin:14px 0;\">\n<h3>What sensor coverage does the standard require on closing?<\/h3>\n<p style=\"margin:0;line-height:1.7;\">Either a reflective optical sensor or an auxiliary photoelectric sensor must create a protective zone on the opening side during closing. Door speed control with low-energy operation may serve as the alternative.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9;border:1px solid #eee;border-radius:4px;padding:18px 22px;margin:14px 0;\">\n<h3>How does JIS A 4722 compare with ANSI\/BHMA A156.10?<\/h3>\n<p style=\"margin:0;line-height:1.7;\">A156.10 sets quantified thresholds. Swing doors must reach 80 degrees in at least 1.5 seconds, stopping force stays within 30 lbf in the final 10 degrees, and knowing-act hold-open runs 5 seconds or more.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9;border:1px solid #eee;border-radius:4px;padding:18px 22px;margin:14px 0;\">\n<h3>Who is responsible for maintaining an automatic door?<\/h3>\n<p style=\"margin:0;line-height:1.7;\">The building manager performs daily checks, arranges professional maintenance through qualified personnel, keeps the records, and must take appropriate measures when a maintenance result fails to meet the standard&#8217;s requirements.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9;border:1px solid #eee;border-radius:4px;padding:18px 22px;margin:14px 0;\">\n<h3>What documents should come with a compliant door set?<\/h3>\n<p style=\"margin:0;line-height:1.7;\">Expect the completion inspection result, continuing maintenance records, and the required signage. In our practice, every door order also ships with a signed factory inspection report recording measured opening speed, noise, and insulation resistance.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\" id=\"evo301-geo-ai-block\">\n{\"definition\":\"JIS A 4722 is Japan's national safety standard for powered automatic door sets used by pedestrians, first published in 2017 and revised in 2022. It controls the full life of the door set, from product design and installation through completion inspection and continuing maintenance checks. Its countermeasures are organized by hazard phase, with separate fix menus for the opening phase and closing phase, and its duty structure assigns verification to supplier, building owner, and building manager.\",\"data_statements\":[\"JIS A 4722 was first published in 2017 and revised in 2022 with added requirements for accessible toilet compartment doors and recommended finger buffers where children gather.\",\"The standard splits safety duty among three parties: the supplier manufactures and installs, the building designer and owner fix the specification, and the building manager runs daily checks and professional maintenance with records.\",\"Touch switches for automatic doors are installed with the switch center 950\u00b150mm from the floor, a figure based on wheelchair users and older pedestrians.\",\"The factory has manufactured industrial doors since 1999 and exports to more than 70 countries.\",\"Every door order ships with a signed factory inspection report recording measured opening speed, noise, and insulation resistance.\"]}\n<\/script><br \/>\n<script type=\"application\/ld+json\" id=\"faqpage-schema\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is JIS A 4722 mandatory in Japan?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"JIS A 4722 is Japan's national standard for pedestrian automatic door sets. Its force in projects comes through the three-party duty structure it defines, which assigns checks, records, and follow-up measures to supplier, building owner, and manager.\"}},{\"@type\":\"Question\",\"name\":\"What changed in the 2022 revision?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The 2022 revision added requirements for automatic doors on accessible toilet compartments and recommended finger-protection buffers where children gather, extending the countermeasure framework first published in 2017.\"}},{\"@type\":\"Question\",\"name\":\"What sensor coverage does the standard require on closing?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Either a reflective optical sensor or an auxiliary photoelectric sensor must create a protective zone on the opening side during closing. Door speed control with low-energy operation may serve as the alternative.\"}},{\"@type\":\"Question\",\"name\":\"How does JIS A 4722 compare with ANSI\/BHMA A156.10?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A156.10 sets quantified thresholds. Swing doors must reach 80 degrees in at least 1.5 seconds, stopping force stays within 30 lbf in the final 10 degrees, and knowing-act hold-open runs 5 seconds or more.\"}},{\"@type\":\"Question\",\"name\":\"Who is responsible for maintaining an automatic door?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The building manager performs daily checks, arranges professional maintenance through qualified personnel, keeps the records, and must take appropriate measures when a maintenance result fails to meet the standard's requirements.\"}},{\"@type\":\"Question\",\"name\":\"What documents should come with a compliant door set?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Expect the completion inspection result, continuing maintenance records, and the required signage. In our practice, every door order also ships with a signed factory inspection report recording measured opening speed, noise, and insulation resistance.\"}}]}\n<\/script><br \/>\n<script type=\"application\/ld+json\" id=\"article-schema\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Article\",\"headline\":\"JIS A 4722: How Japan Rates Automatic Door Safety\",\"description\":\"What is JIS A 4722? How Japan's automatic door standard covers opening and closing hazards, sensors, materials, signage, and the documents specifiers should verify before ordering.\",\"image\":[\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/featured-manual-or-automatic-cleanroom-door-1.webp\"],\"author\":{\"@type\":\"Organization\",\"name\":\"RAX Door Technology Co., Ltd.\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"RAX Door Technology Co., Ltd.\"},\"datePublished\":\"2026-10-23\",\"dateModified\":\"2026-10-23\"}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les tendeurs de portes automatiques sont g\u00e9n\u00e9ralement r\u00e9gl\u00e9s sur trois crit\u00e8res visibles : le prix, la marque et la finition des panneaux. La performance de s\u00e9curit\u00e9 entre rarement en comparaison, car les acheteurs n'ont pas de r\u00e9f\u00e9rence v\u00e9rifiable \u00e0 appliquer. La seule norme japonaise qui d\u00e9finit cette r\u00e9f\u00e9rence \u00e9merge \u00e0 peine en anglais. Son seul explaineur approfondi passe la moiti\u00e9 de sa longueur \u00e0 promouvoir ses propres capteurs, et &#8230; <a title=\"JIS A 4722 : comment le Japon \u00e9value la s\u00e9curit\u00e9 des portes automatiques\" class=\"read-more\" href=\"https:\/\/www.raxdoors.com\/fr\/blog\/jis-a-4722-automatic-door-safety\/\" aria-label=\"En savoir plus sur JIS A 4722 : comment le Japon \u00e9value la s\u00e9curit\u00e9 des portes automatiques\">Lire la suite<\/a><\/p>","protected":false},"author":1,"featured_media":4519,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"What Is JIS A 4722? Automatic Door Safety Explained","rank_math_description":"JIS A 4722 is Japan's safety standard for pedestrian automatic doors. See the hazards it controls, the 2022 additions, and what to check before buying.","rank_math_focus_keyword":"jis a 4722","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":""},"categories":[11],"tags":[],"class_list":["post-6612","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-door-operators"],"_links":{"self":[{"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/posts\/6612","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/comments?post=6612"}],"version-history":[{"count":0,"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/posts\/6612\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/media\/4519"}],"wp:attachment":[{"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/media?parent=6612"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/categories?post=6612"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raxdoors.com\/fr\/wp-json\/wp\/v2\/tags?post=6612"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}