{"id":574,"date":"2026-08-03T15:44:27","date_gmt":"2026-08-03T15:44:27","guid":{"rendered":"https:\/\/www.raxdoors.com\/products\/clean-room-doors\/interlock-clean-room-door\/"},"modified":"2026-09-12T21:25:04","modified_gmt":"2026-09-12T13:25:04","slug":"interlock-clean-room-door","status":"publish","type":"page","link":"https:\/\/www.raxdoors.com\/es\/clean-room-doors\/interlock-clean-room-door\/","title":{"rendered":"Puerta de sala limpia de interbloqueo"},"content":{"rendered":"\n<!-- deliverable: wp-fragment -->\n<!--\n================================================================================\nRAX DOOR TECHNOLOGY \u2014 Interlock Clean Room Door (Clean Room Doors)\nEnriched with researched technical data. main.css classes only.\n================================================================================\n-->\n\n<div class=\"page-shell\">\n\n  <section class=\"section-dark page-hero section\">\n    <div class=\"container-xl\">\n      <nav class=\"page-breadcrumbs\" aria-label=\"Breadcrumb\">\n        <a href=\"https:\/\/www.raxdoors.com\/\">Home<\/a>\n        <span class=\"page-breadcrumbs__separator\">\/<\/span>\n        <a href=\"https:\/\/www.raxdoors.com\/products\/\">Products<\/a>\n        <span class=\"page-breadcrumbs__separator\">\/<\/span>\n        <a href=\"\/clean-room-doors\/\">Clean Room Doors<\/a>\n        <span class=\"page-breadcrumbs__separator\">\/<\/span>\n        <span>Interlock Clean Room Door<\/span>\n      <\/nav>\n      <div class=\"page-hero__layout\">\n        <div class=\"page-section__copy\">\n          <span class=\"eyebrow\">Clean Room Doors \u00b7 Manufacturer since 1999<\/span>\n          <h1>Interlock Clean Room Door<\/h1>\n          <div class=\"btn-group\">\n            <span class=\"pill\">Airlock System \u00b7 Up to 1 m\/s<\/span>\n            <span class=\"pill\">CE \u00b7 EN 13241<\/span>\n            <span class=\"pill\">Full technical drawings<\/span>\n          <\/div>\n          <div class=\"page-actions\">\n            <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n            <a class=\"btn btn-outline\" href=\"#specs\">View Specifications<\/a>\n          <\/div>\n        <\/div>\n        <div class=\"page-hero__media\">\n          <img decoding=\"async\" class=\"rax-hero-img\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/clean-room-doors-facility-selection-architecture.webp\" alt=\"Interlock Clean Room Door \u2014 RAX Door Technology\">\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">01 \u00b7 Overview<\/span>\n        <h2>Airlock Protection for Clean Rooms<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <p>Interlock clean room doors are designed for airlock systems where two doors cannot open simultaneously. This prevents direct air exchange between clean and non-clean zones, maintaining clean room classification and preventing contamination ingress. Unlike standard doors that operate independently, interlock doors feature electronic control systems that coordinate door operation.<\/p>\n        <p>RAX manufactures interlock clean room doors with stainless steel SS304\/SS316 panels, multi-layer EPDM sealing systems, and servo motor drive with interlock control. Opening speeds up to 1 m\/s minimize exposure time during each opening cycle. Airtight sealing maintains positive pressure differentials.<\/p>\n        <p>These doors are essential for pharmaceutical clean rooms, biotechnology laboratories, semiconductor manufacturing facilities, hospital isolation rooms, and any environment where airlock protection is required.<\/p>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">02 \u00b7 Key Features<\/span>\n        <h2>Engineered for Airlock Systems<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"grid-3\">\n          <div class=\"card\"><h3>Electronic Interlock Control<\/h3><p>Two doors cannot open simultaneously. Electronic control system coordinates door operation. Prevents direct air exchange between clean and non-clean zones. Maintains clean room classification.<\/p><\/div>\n          <div class=\"card\"><h3>Stainless Steel Construction<\/h3><p>SS304\/SS316 stainless steel panels resist bacterial growth and are easy to clean and sanitize. Non-porous surfaces prevent contamination accumulation. Suitable for washdown environments.<\/p><\/div>\n          <div class=\"card\"><h3>Multi-Layer Airtight Sealing<\/h3><p>Multiple EPDM seals on all four sides create airtight barrier. Perimeter seals, inter-panel seals, and bottom seals work together to prevent air exchange. Maintains positive pressure differentials.<\/p><\/div>\n          <div class=\"card\"><h3>High-Speed Operation<\/h3><p>Opening speeds up to 1 m\/s with servo motor drive. Frequency converter for smooth acceleration\/deceleration. Minimizes exposure time during each opening cycle.<\/p><\/div>\n          <div class=\"card\"><h3>Positive Pressure Maintenance<\/h3><p>Fast operation + airtight sealing maintains positive pressure in clean rooms. Critical for preventing contamination ingress. Supports ISO 14644 clean room classification.<\/p><\/div>\n          <div class=\"card\"><h3>Smart Control<\/h3><p>PLC-based interlock control with LCD display. Integration with clean room monitoring systems. Remote operation and diagnostics. Programmable speeds and delay times.<\/p><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section id=\"specs\" class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">03 \u00b7 Technical Data<\/span>\n        <h2>Technical Specifications<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"data-table-wrap\">\n          <table class=\"data-table\">\n            <tr><td class=\"row-label\">Product<\/td><td>Interlock Clean Room Door (also: Airlock Door \u00b7 Clean Room Airlock System)<\/td><\/tr>\n            <tr><td class=\"row-label\">Category<\/td><td>Clean Room Doors<\/td><\/tr>\n            <tr><td class=\"row-label\">Panel material<\/td><td>Stainless steel SS304\/SS316<\/td><\/tr>\n            <tr><td class=\"row-label\">Sealing system<\/td><td>Multi-layer EPDM seals (perimeter + inter-panel + bottom)<\/td><\/tr>\n            <tr><td class=\"row-label\">Interlock control<\/td><td>Electronic interlock (two doors cannot open simultaneously)<\/td><\/tr>\n            <tr><td class=\"row-label\">Opening speed<\/td><td>Up to 1 m\/s (adjustable)<\/td><\/tr>\n            <tr><td class=\"row-label\">Closing speed<\/td><td>Up to 0.8 m\/s (adjustable)<\/td><\/tr>\n            <tr><td class=\"row-label\">Motor type<\/td><td>Servo motor with frequency converter<\/td><\/tr>\n            <tr><td class=\"row-label\">Motor protection<\/td><td>IP65 sealed housing<\/td><\/tr>\n            <tr><td class=\"row-label\">Width range<\/td><td>1,000\u20134,000 mm (custom)<\/td><\/tr>\n            <tr><td class=\"row-label\">Height range<\/td><td>1,500\u20134,000 mm (custom)<\/td><\/tr>\n            <tr><td class=\"row-label\">Safety features<\/td><p>Photocells, pressure-sensitive edges, emergency stop<\/p><\/td><\/tr>\n            <tr><td class=\"row-label\">Certification<\/td><p>CE EN 13241 \/ EN 12453 (held); ISO 9001:2015; SGS material reports<\/p><\/td><\/tr>\n            <tr><td class=\"row-label\">Order<\/td><p>Custom engineered to your opening size and clean room requirements<\/p><\/td><\/tr>\n          <\/table>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;text-align:center;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">04 \u00b7 Applications<\/span>\n        <h2>Where Interlock Doors Excel<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"grid-3\">\n          <div class=\"card\"><h3>Pharmaceutical Clean Rooms<\/h3><p>GMP-compliant environments require airlock protection. Interlock doors prevent direct air exchange between zones. Airtight sealing maintains positive pressure. Fast operation minimizes exposure time.<\/p><\/div>\n          <div class=\"card\"><h3>Biotechnology Laboratories<\/h3><p>BSL-2 and BSL-3 laboratories require strict containment. Interlock doors prevent pathogen escape. Smooth surfaces easy to decontaminate. Fast operation supports workflow efficiency.<\/p><\/div>\n          <div class=\"card\"><h3>Semiconductor Manufacturing<\/h3><p>Clean room environments for chip manufacturing. Interlock doors prevent particle ingress. Smooth surfaces minimize particle generation. Fast operation supports production throughput.<\/p><\/div>\n          <div class=\"card\"><h3>Hospital Isolation Rooms<\/h3><p>Negative pressure isolation rooms require airlock protection. Interlock doors prevent pathogen spread. Smooth surfaces easy to disinfect. Fast operation supports emergency access.<\/p><\/div>\n          <div class=\"card\"><h3>Food Processing Facilities<\/h3><p>HACCP-compliant environments require contamination control. Interlock doors prevent cross-contamination between zones. Smooth surfaces resist bacterial growth.<\/p><\/div>\n          <div class=\"card\"><h3>Research Laboratories<\/h3><p>University and industrial research labs with clean room requirements. Interlock doors maintain clean room classification. Fast operation supports research workflow.<\/p><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">05 \u00b7 Customization<\/span>\n        <h2>OEM \/ ODM &amp; Customization<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <p>RAX supports full private-label production of the Interlock Clean Room Door: custom panel material (SS304\/SS316), sealing configuration, interlock control programming, motor specification, packaging printing and installation-manual translation (EN\/ES\/FR\/AR\/RU). Start with an OEM sample and scale to container-load branded production. Custom molds and tooling records are archived for up to 5 years \u2014 no extra tooling fee on repeat orders, all under strict NDA.<\/p>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">06 \u00b7 Compliance<\/span>\n        <h2>Applicable Standards<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <div class=\"grid-3\">\n          <div class=\"card\"><h3>EN 13241:2003+A2:2016<\/h3><p>Core CE product standard for industrial, commercial, and garage doors. Covers both manual and powered doors. Requires Declaration of Performance (DoP) under CPR 305\/2011.<\/p><\/div>\n          <div class=\"card\"><h3>EN 12453:2001<\/h3><p>Safety requirements for powered doors. Specifies force limiting, safety devices, and control system requirements.<\/p><\/div>\n          <div class=\"card\"><h3>ISO 14644<\/h3><p>Clean room classification standard. Interlock doors support clean room classification by maintaining positive pressure and preventing contamination ingress.<\/p><\/div>\n          <div class=\"card\"><h3>CE Marking<\/h3><p>Mandatory for export to EU\/UK markets. RAX provides CE technical file and Declaration of Performance with every shipment.<\/p><\/div>\n        <\/div>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section\">\n    <div class=\"container-xl\">\n      <div class=\"section-heading\">\n        <span class=\"eyebrow\">07 \u00b7 Why RAX<\/span>\n        <h2>Why Buyers Choose RAX for Interlock Doors<\/h2>\n      <\/div>\n      <div class=\"divider\"><\/div>\n      <div class=\"flow-top-lg\">\n        <ul>\n          <li><strong>27-year zero-leak track record<\/strong> \u2014 5,000+ overseas projects delivered since 1999, with no leakage complaints on door bodies<\/li>\n          <li><strong>Electronic interlock control<\/strong> \u2014 two doors cannot open simultaneously, preventing air exchange<\/li>\n          <li><strong>Stainless steel construction<\/strong> \u2014 SS304\/SS316 panels resist bacterial growth and are easy to clean<\/li>\n          <li><strong>Multi-layer airtight sealing<\/strong> \u2014 perimeter + inter-panel + bottom seals prevent air exchange<\/li>\n          <li><strong>Deep customization<\/strong> \u2014 every door engineered to your exact size, specification, and clean room requirements<\/li>\n          <li><strong>Full documentation package<\/strong> \u2014 English installation manual, wiring diagrams, CE technical file<\/li>\n        <\/ul>\n      <\/div>\n      <div class=\"page-actions\" style=\"margin-top:2rem;\">\n        <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-soft section\">\n    <div class=\"container-xl\">\n      <div class=\"faq-split\">\n        <aside class=\"faq-split__left\" aria-label=\"FAQ overview\">\n          <span class=\"faq-split__eyebrow\">08 \u00b7 Buyer FAQ<\/span>\n          <h2 class=\"faq-split__title\">Interlock clean room door questions<span class=\"accent\">,<\/span> answered<span class=\"accent\">.<\/span><\/h2>\n          <p class=\"faq-split__lead\">Technical answers on interlock control, airlock systems, clean rooms, and applications.<\/p>\n          <a class=\"faq-split__cta\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a quote\n            <svg viewBox=\"0 0 24 24\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"2.4\" stroke-linecap=\"round\" stroke-linejoin=\"round\" aria-hidden=\"true\">\n              <line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"><\/line>\n              <polyline points=\"12 5 19 12 12 19\"><\/polyline>\n            <\/svg>\n          <\/a>\n        <\/aside>\n        <div class=\"faq-split__right\">\n          <div class=\"faq-stack\">\n            <details><summary>How does interlock control work?<\/summary><div class=\"faq-stack__answer\"><p>Electronic interlock system ensures two doors cannot open simultaneously. When one door opens, the other door is locked. Prevents direct air exchange between clean and non-clean zones.<\/p><\/div><\/details>\n            <details><summary>Are interlock doors suitable for clean rooms?<\/summary><div class=\"faq-stack__answer\"><p>Yes. Smooth stainless steel panels, multi-layer sealing maintains positive pressure. Interlock control prevents contamination ingress. Supports ISO 14644 clean room classification.<\/p><\/div><\/details>\n            <details><summary>What is the opening speed?<\/summary><div class=\"faq-stack__answer\"><p>Up to 1 m\/s opening speed, 0.8 m\/s closing speed. Speed is adjustable via PLC control system. Servo motor with frequency converter ensures smooth operation.<\/p><\/div><\/details>\n            <details><summary>Can interlock doors integrate with clean room monitoring?<\/summary><div class=\"faq-stack__answer\"><p>Yes. PLC-based interlock control integrates with clean room monitoring systems. Remote operation and diagnostics available. Programmable speeds and delay times.<\/p><\/div><\/details>\n            <details><summary>Do you provide installation?<\/summary><div class=\"faq-stack__answer\"><p>No \u2014 RAX is a pure manufacturer. Doors ship with English installation manuals, wiring diagrams, and remote support.<\/p><\/div><\/details>\n            <details><summary>What is the lead time and warranty?<\/summary><div class=\"faq-stack__answer\"><p>Standard configurations: 12\u201320 days. Custom first order: 20\u201335 days. Repeat orders: 15\u201320 days. Warranty: panels 10 years, motor and control 5 years.<\/p><\/div><\/details>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n  <section class=\"section-dark section\">\n    <div class=\"container-xl\">\n      <div class=\"center-stack\">\n        <span class=\"eyebrow\">09 \u00b7 Get Started<\/span>\n        <h2>Get Your Interlock Clean Room Door Proposal<\/h2>\n        <p class=\"lead\">Send your opening size, clean room classification, and interlock requirements \u2014 we reply with a specification, lead time, and quote.<\/p>\n        <div class=\"btn-group\">\n          <a class=\"btn btn-primary\" href=\"https:\/\/www.raxdoors.com\/contact-us\/\">Get a Free Quote<\/a>\n        <\/div>\n      <\/div>\n    <\/div>\n  <\/section>\n\n<\/div>\n\n<script type=\"application\/ld+json\">{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"Product\",\n      \"name\": \"Interlock Clean Room Door\",\n      \"category\": \"Clean Room Doors\",\n      \"brand\": {\n        \"@type\": \"Brand\",\n        \"name\": \"RAX Door Technology\"\n      },\n      \"manufacturer\": {\n        \"@type\": \"Organization\",\n        \"name\": \"RAX Door Technology Co., Ltd.\",\n        \"url\": \"https:\/\/www.raxdoors.com\/#organization\"\n      },\n      \"description\": \"Custom Interlock Clean Room Door manufactured to order by RAX Door Technology. Electronic interlock control, stainless steel SS304\/SS316 panels, multi-layer airtight sealing. CE EN 13241\/12453, ISO 9001:2015. Manufacturer since 1999.\",\n      \"offers\": {\n        \"@type\": \"Offer\",\n        \"availability\": \"https:\/\/schema.org\/InStock\",\n        \"priceCurrency\": \"USD\",\n        \"price\": \"1100\",\n        \"description\": \"Made to order \u2014 request a quote\",\n        \"url\": \"https:\/\/www.raxdoors.com\/clean-room-doors\/interlock-clean-room-door\/\",\n        \"priceValidUntil\": \"2027-12-31\",\n        \"validFrom\": \"2026-09-12\",\n        \"hasMerchantReturnPolicy\": {\n          \"@type\": \"MerchantReturnPolicy\",\n          \"applicableCountry\": \"US\",\n          \"returnPolicyCategory\": \"https:\/\/schema.org\/MerchantReturnNotPermitted\",\n          \"returnMethod\": \"https:\/\/schema.org\/ReturnByMail\",\n          \"returnFees\": \"https:\/\/schema.org\/NonReturnableFee\"\n        },\n        \"shippingDetails\": {\n          \"@type\": \"OfferShippingDetails\",\n          \"shippingRate\": {\n            \"@type\": \"MonetaryAmount\",\n            \"value\": \"0\",\n            \"currency\": \"USD\"\n          },\n          \"shippingDestination\": {\n            \"@type\": \"DefinedRegion\",\n            \"addressCountry\": \"US\"\n          },\n          \"deliveryTime\": {\n            \"@type\": \"ShippingDeliveryTime\",\n            \"handlingTime\": {\n              \"@type\": \"QuantitativeValue\",\n              \"minValue\": 15,\n              \"maxValue\": 45,\n              \"unitCode\": \"DAY\"\n            },\n            \"transitTime\": {\n              \"@type\": \"QuantitativeValue\",\n              \"minValue\": 7,\n              \"maxValue\": 30,\n              \"unitCode\": \"DAY\"\n            }\n          }\n        }\n      }\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"itemListElement\": [\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 1,\n          \"name\": \"Home\",\n          \"item\": \"https:\/\/www.raxdoors.com\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 2,\n          \"name\": \"Products\",\n          \"item\": \"https:\/\/www.raxdoors.com\/products\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 3,\n          \"name\": \"Clean Room Doors\",\n          \"item\": \"\/clean-room-doors\/\"\n        },\n        {\n          \"@type\": \"ListItem\",\n          \"position\": 4,\n          \"name\": \"Interlock Clean Room Door\",\n          \"item\": \"\/clean-room-doors\/interlock-clean-room-door\/\"\n        }\n      ]\n    },\n    {\n      \"@type\": \"FAQPage\",\n      \"mainEntity\": [\n        {\n          \"@type\": \"Question\",\n          \"name\": \"How does interlock control work?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Electronic interlock system ensures two doors cannot open simultaneously. Prevents direct air exchange between clean and non-clean zones.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Are interlock doors suitable for clean rooms?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes. Smooth stainless steel panels, multi-layer sealing maintains positive pressure. Supports ISO 14644 clean room classification.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is the opening speed?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Up to 1 m\/s opening speed, 0.8 m\/s closing speed. Speed is adjustable via PLC control system.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Can interlock doors integrate with clean room monitoring?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Yes. PLC-based interlock control integrates with clean room monitoring systems. Remote operation and diagnostics available.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"Do you provide installation?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"No \u2014 RAX is a pure manufacturer. Doors ship with English installation manuals, wiring diagrams, and remote support.\"\n          }\n        },\n        {\n          \"@type\": \"Question\",\n          \"name\": \"What is the lead time and warranty?\",\n          \"acceptedAnswer\": {\n            \"@type\": \"Answer\",\n            \"text\": \"Standard configurations: 12\u201320 days. Custom first order: 20\u201335 days. Repeat orders: 15\u201320 days. Warranty: panels 10 years, motor and control 5 years.\"\n          }\n        }\n      ]\n    }\n  ]\n}<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>Inicio \/ Productos \/ Puertas para Sala Blanca \/ Puerta de Interbloqueo para Sala Blanca Puertas para Sala Blanca \u00b7 Fabricante desde 1999 Sistema de esclusa de puerta de interbloqueo para sala blanca \u00b7 Hasta 1 m\/s CE \u00b7 EN 13241 Planos t\u00e9cnicos completos Solicite una Cotizaci\u00f3n Gratis Ver Especificaciones 01 \u00b7 Visi\u00f3n general Protecci\u00f3n con esclusa para salas blancas Las puertas de interbloqueo para sala blanca \u2026 <a title=\"Puerta de sala limpia de interbloqueo\" class=\"read-more\" href=\"https:\/\/www.raxdoors.com\/es\/clean-room-doors\/interlock-clean-room-door\/\" aria-label=\"Leer m\u00e1s sobre Interlock Clean Room Door\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":1,"featured_media":0,"parent":499,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-574","page","type-page","status-publish"],"_links":{"self":[{"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/pages\/574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/comments?post=574"}],"version-history":[{"count":8,"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/pages\/574\/revisions"}],"predecessor-version":[{"id":4102,"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/pages\/574\/revisions\/4102"}],"up":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/pages\/499"}],"wp:attachment":[{"href":"https:\/\/www.raxdoors.com\/es\/wp-json\/wp\/v2\/media?parent=574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}