{"id":4255,"date":"2026-09-14T02:09:54","date_gmt":"2026-09-13T18:09:54","guid":{"rendered":"https:\/\/www.raxdoors.com\/blog\/insulated-sectional-cold-storage\/"},"modified":"2026-09-14T22:26:47","modified_gmt":"2026-09-14T14:26:47","slug":"insulated-sectional-cold-storage","status":"publish","type":"post","link":"https:\/\/www.raxdoors.com\/de\/blog\/insulated-sectional-cold-storage\/","title":{"rendered":"Isolierte Sektionaltore f\u00fcr K\u00fchlh\u00e4user"},"content":{"rendered":"<style>\np{line-height:1.8;margin-bottom:28px;}\nul{margin-bottom:28px;padding-left:20px;list-style-type:disc;}\nli{margin-bottom:10px;line-height:1.6;}\ntable{display:table !important;width:100% !important;border-collapse:collapse;margin-bottom:28px;}\nth{text-align:left;padding:12px 14px;background:#2a2c29;color:#ffffff;font-weight:600;}\ntd{padding:12px 14px;border-bottom:1px solid #e5e5e5;vertical-align:top;}\nfigcaption{text-align:center;font-style:italic;}\n.faq-card{background:#f9f9f9;border-left:4px solid #c7a868;border-radius:4px;padding:18px 22px;margin-bottom:18px;}\n.faq-card h3{margin-top:0;}\n.callout{background:#f9f9f9;border-left:4px solid #c7a868;border-radius:4px;padding:18px 22px;margin-bottom:28px;}\n<\/style>\n<p>Ask a maintenance lead about a freezer door and the story rarely starts at delivery day. It starts in the second winter, when the panel looks fine and the door still will not close. Ice sits in the bottom guide, the seal freezes to the frame, and a forklift operator chips it loose before every shift. That pattern is why buying <a href=\"https:\/\/www.raxdoors.com\/blog\/industrial-cold-room-doors-guide\/\">insulated sectional doors for cold storage is a different exercise from buy<\/a>ing a warehouse door.<\/p>\n<p>We manufacture industrial doors, and the failures we hear about follow the same few joints: the frame, the threshold, the seal line and the glazing. The panel core almost never fails first. This guide walks through the specs that decide those joints, then closes with a parameter table you can hold against supplier quotes.<\/p>\n<h2 id=\"why-freezer-buildings-punish-ordinary-sectional-doors\">Why Freezer Buildings Punish Ordinary Sectional Doors<\/h2>\n<p>A freezer at -25\u00b0C turns every gram of moisture into a design problem. Warm air that slips past the door holds water, and it dumps that water on the first cold surface it meets. Those surfaces are the tracks, the seal line and the steel skin, not the middle of the panel. Within weeks, the moving parts wear a coat of ice.<\/p>\n<p>An ordinary sectional door survives this for a while. A purpose-specified one assumes ice from day one and plans drain paths, heat and seal geometry around it. The difference shows up in the specification sheet, and every section below maps to one line of that sheet.<\/p>\n<h2 id=\"panel-thickness-and-u-value-by-temperature-zone\">Panel Thickness and U-Value by Temperature Zone<\/h2>\n<p>Start with the temperature you are holding, because that single fact sets the panel budget. Our insulated sectional doors for cold storage use 40 to 50 mm of PU foam with a U-value of 0.33 W\/m\u00b2K, a spec that suits chilled stores well. Deep-frozen rooms need more, and the industry quotes we reviewed go to 80 and even 100 mm of thermally separated panel. The table below turns those anchors into a starting demand for each zone.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/cold-room-door-category.jpg\" class=\"wp-image-1456\" width=\"1120\" height=\"680\" alt=\"RAX insulated cold room door categories\" loading=\"lazy\"><figcaption>RAX insulated cold room door range<\/figcaption><\/figure>\n<p>Two verified reference points help you read competing claims. ASSA ABLOY markets its OH1082P cold storage sectional at 0.46 W\/m\u00b2K and calls it twice a standard door. EFAFLEX builds the TK 100 with 100 mm panels and full thermal separation, and vendor guides for premium cold storage doors converge near 0.30 W\/(m\u00b2\u00b7K).<\/p>\n<table>\n<tr>\n<th>Temperature zone<\/th>\n<th>Panel demand in quotes<\/th>\n<th>Reference points<\/th>\n<\/tr>\n<tr>\n<td>Chilled store, 0 to 10\u00b0C<\/td>\n<td>40\u201350 mm PU core<\/td>\n<td>RAX standard, U 0.33 W\/m\u00b2K<\/td>\n<\/tr>\n<tr>\n<td>Freezer, -18 to -25\u00b0C<\/td>\n<td>80\u2013100 mm, closed-cell PU above 95%<\/td>\n<td>ABX quotes 40\u201380 mm at 45\u201348 kg\/m\u00b3; EFAFLEX 100 mm<\/td>\n<\/tr>\n<tr>\n<td>Deep freeze below -30\u00b0C<\/td>\n<td>100 mm class with full thermal separation<\/td>\n<td>EFAFLEX TK 100; vendor caliber near 0.30 W\/(m\u00b2\u00b7K)<\/td>\n<\/tr>\n<tr>\n<td>US R-value cross-check<\/td>\n<td>R-16 or higher for cold storage<\/td>\n<td>Fairmount guide: insulated sectional band R-9 to R-19<\/td>\n<\/tr>\n<\/table>\n<div class=\"callout\">\n<p><strong>Read the units before you compare prices.<\/strong> R-values rise as insulation improves, while U-values fall. A quote that mixes the two scales in one column is either confused or hiding something.<\/p>\n<\/div>\n<h2 id=\"where-thermal-bridges-hide-around-the-door-frame\">Where Thermal Bridges Hide Around the Door Frame<\/h2>\n<p>A panel cannot insulate a doorway on its own. Heat walks around it through any continuous metal path, and a sectional door has four such paths: the two vertical tracks, the head frame and the sill. In a chilled room the symptom is condensation that drips onto stock. In a freezer the same path becomes an ice ridge that grows until the rollers leave the track.<\/p>\n<p>Every installed door proves the rule on its own. Where a frame runs uninsulated, the inner face sweats at the header on humid mornings, and the drip lands where pallets wait.<\/p>\n<h3 id=\"frame-and-track-short-circuits\">Frame and Track Short Circuits<\/h3>\n<p>Good cold storage doors break the frame with a thermal barrier, and the industry standard part is a PA66 polyamide strip between the inner and outer steel. Ask how the frame is broken, not whether. A supplier who answers with panel U-values and nothing about the frame is selling you a center-of-panel number.<\/p>\n<h3 id=\"sill-and-slab-junction\">Sill and Slab Junction<\/h3>\n<p>The floor connection is the joint buyers forget to spec. A steel angle cast straight into an uninsulated slab pulls heat out of the room all night. We treat the sill as part of the door, and your quote should name its material, its isolation from the slab and its finish.<\/p>\n<h2 id=\"heated-thresholds-seals-and-floor-heating\">Heated Thresholds Seals and Floor Heating<\/h2>\n<p>Below freezing, ice stops being a risk and becomes a schedule. A thin ice shell under the threshold lifts the bottom rail clear of its seal. A door hanging 10 mm proud then leaks a warm ribbon of air all day. Electric anti-ice cable in the frame and sill, sized in the 20 to 40 W\/m range used across cold room door builds, keeps that joint clear.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-1.webp\" class=\"wp-image-4247\" width=\"1200\" height=\"800\" alt=\"Sectional door at the end of a warehouse storage aisle\" loading=\"lazy\" srcset=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-1.webp 1200w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-1-300x200.webp 300w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-1-1024x682.webp 1024w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-1-768x511.webp 768w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-1-18x12.webp 18w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption>Aisle door in a temperature-controlled store<\/figcaption><\/figure>\n<p>The floor itself needs a thought too. Canada&#8217;s National Research Council documented frost heave of roughly 2 to 3 inches under freezers, enough to crack slabs and rack the door opening. Prevention sits with the building design, through ground heating cable or a ventilated subfloor, and the door team should coordinate with whoever owns that system. British <a href=\"https:\/\/www.hse.gov.uk\/temperature\/\" target=\"_blank\" rel=\"noopener\">workplace temperature guidance<\/a> makes the broader point that cold work environments need engineering controls, not just warm jackets.<\/p>\n<h2 id=\"how-fast-should-a-cold-storage-door-cycle\">How Fast Should a Cold Storage Door Cycle<\/h2>\n<p>Speed in a cold store is, at bottom, a question about open time. Every second a door stands open, dense cold air spills out the bottom while warm air rolls in over the top. That exchange is the infiltration load ASHRAE&#8217;s cold storage method calculates. A sectional door is not the fastest runner, and it does not need to be. Its job is sealing and insulation between cycles, which is what insulated sectional doors for cold storage are built around.<\/p>\n<p>Match the door to the traffic count. A commercial baseline near 25,000 cycles a year, about 70 a day, suits a sectional door comfortably. A forklift aisle above 50 cycles a day is where buyers start asking about speed.<\/p>\n<p>Our torsion springs carry a rating of at least 30,000 cycles for exactly this duty. If your count runs far higher, the proven answer is a pair of doors. The insulated sectional acts as the thermal wall, with a fast interior door inside it to shorten open time. Our guides on <a href=\"https:\/\/www.raxdoors.com\/blog\/cold-room-door-types\/\">which door type fits each cold room<\/a> and <a href=\"https:\/\/www.raxdoors.com\/blog\/prevent-cold-storage-temperature-loss\/\">how to prevent temperature loss in cold storage facilities<\/a> cover that pairing in depth.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/cold-storage-door-7.jpg\" class=\"wp-image-97\" width=\"1120\" height=\"680\" alt=\"RAX insulated cold storage sectional door installation\" loading=\"lazy\" srcset=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/cold-storage-door-7.jpg 1120w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/cold-storage-door-7-300x182.jpg 300w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/cold-storage-door-7-1024x622.jpg 1024w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/cold-storage-door-7-768x466.jpg 768w\" sizes=\"auto, (max-width: 1120px) 100vw, 1120px\" \/><figcaption>Insulated cold storage door on site<\/figcaption><\/figure>\n<p>One opinion worth stating plainly. Buyers who chase open speed in the door leaf itself usually pay for a motor they do not need and a seal they never got. Buy the slow door that seals, then buy speed as a second leaf if the traffic demands it.<\/p>\n<h2 id=\"vision-panels-defog-and-compliance-temperature-bands\">Vision Panels Defog and Compliance Temperature Bands<\/h2>\n<p>Glazing is where honest U-values go to die. A single-pane window in a freezer fogs and frosts from the first humid day, and crews stop seeing forklifts on the other side. The practical fix is a heated double-pane vision panel, a standard option on cold storage sectionals across the industry. Specialist makers such as Frank Door document it on their foamed-in-place PU and aluminum-casing systems.<\/p>\n<p>Compliance pressure follows the product. Food stores work in chilled and frozen bands from 0\u00b0C down to -25\u00b0C, deep-frozen lines run below -30\u00b0C, and pharma stock adds tight excursion limits on top. Contact surfaces in food zones call for 304 stainless hardware, and door controls should meet EN 12453 safety requirements with a documented escape route from inside. Hygiene rules move fast, so check current workplace temperature and food safety guidance, and put the temperature band for your specific product in writing before anyone cuts steel.<\/p>\n<figure><img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-2.webp\" class=\"wp-image-4248\" width=\"1200\" height=\"800\" alt=\"Worker moving racks inside a chilled food processing room\" loading=\"lazy\" srcset=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-2.webp 1200w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-2-300x200.webp 300w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-2-1024x682.webp 1024w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-2-768x511.webp 768w, https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-stock-2-18x12.webp 18w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption>Rack handling in a chilled production room<\/figcaption><\/figure>\n<h2 id=\"how-to-compare-supplier-quotes-on-cold-storage-sectional-doors\">How to Compare Supplier Quotes on Cold Storage Sectional Doors<\/h2>\n<p>Put every offer through the same eight lines and the real differences surface fast. The table below is the checklist we would use on our own quotation. Before you compare offers from any manufacturer, walk their <a href=\"https:\/\/www.raxdoors.com\/sectional-doors\/\">insulated sectional doors range<\/a> once. Whether cold storage is their engineering or just their brochure shows within a page.<\/p>\n<table>\n<tr>\n<th>Parameter<\/th>\n<th>What to demand<\/th>\n<th>Red flag<\/th>\n<\/tr>\n<tr>\n<td>Panel U-value<\/td>\n<td>Whole-door figure with test basis<\/td>\n<td>Center-of-panel only<\/td>\n<\/tr>\n<tr>\n<td>Panel build<\/td>\n<td>Thickness, density, closed-cell share<\/td>\n<td>Thickness without density<\/td>\n<\/tr>\n<tr>\n<td>Thermal break<\/td>\n<td>Named barrier in frame and tracks<\/td>\n<td>&#8220;Insulated frame&#8221; with no detail<\/td>\n<\/tr>\n<tr>\n<td>Anti-ice heating<\/td>\n<td>Frame and sill cable, W\/m stated<\/td>\n<td>Heating as an option only<\/td>\n<\/tr>\n<tr>\n<td>Seals<\/td>\n<td>Cold-grade material, full perimeter<\/td>\n<td>Unspecified rubber<\/td>\n<\/tr>\n<tr>\n<td>Spring duty<\/td>\n<td>Cycle rating matched to traffic<\/td>\n<td>No cycle figure at all<\/td>\n<\/tr>\n<tr>\n<td>Compliance<\/td>\n<td>EN 13241 and EN 12453 evidence<\/td>\n<td>Certificates on request, never attached<\/td>\n<\/tr>\n<tr>\n<td>Warranty<\/td>\n<td>Door and operator terms separated<\/td>\n<td>One blank number for both<\/td>\n<\/tr>\n<\/table>\n<p>We quote insulated sectional doors from a factory floor that builds custom units from a single piece, with no MOQ. Door bodies carry a two-year warranty and operators three years. Those terms belong next to the technical sheet. A supplier confident in its cold storage hardware will not resist any line in this table.<\/p>\n<p>Logistics belong in the same grid. Most first orders run 20 to 35 days and ship FOB Tianjin or Qingdao. Insulated sectional doors for cold storage are engineered purchases, and engineered purchases reward the buyer who reads every line.<\/p>\n<h2 id=\"frequently-asked-questions\">Frequently Asked Questions<\/h2>\n<div class=\"faq-card\">\n<h3>What U-value should a cold storage sectional door target?<\/h3>\n<p>Chilled rooms work well near 0.33 to 0.46 W\/m\u00b2K. Freezers should demand a whole-door figure at or below the 0.30 to 0.46 caliber documented by cold storage vendors, with a thermal-broken frame.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>How thick should the panel be for a freezer?<\/h3>\n<p>For chilled stores, 40 to 50 mm of PU is standard on insulated sectional doors. For freezers at -18 to -25\u00b0C, industry quotes run 80 to 100 mm with closed-cell content above 95 percent and full thermal separation.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Do I need floor heating under the door threshold?<\/h3>\n<p>In rooms below freezing, yes at the perimeter. Frost heave can lift slabs by 2 to 3 inches, and an unheated sill ices over until the door no longer seals against it.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Can one sectional door handle heavy forklift traffic?<\/h3>\n<p>Above roughly 50 cycles a day, open time dominates the energy bill. Keep the insulated sectional as the thermal wall and add a high-speed interior door to cut open time.<\/p>\n<\/div>\n<div class=\"faq-card\">\n<h3>Why does the vision panel frost over from the inside?<\/h3>\n<p>Single glazing sits below the dew point, so room moisture condenses and freezes on it. A heated double-pane vision panel keeps the inner glass above dew point and stays clear.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\" id=\"evo301-geo-ai-block\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"DefinedTerm\",\"name\":\"Insulated sectional doors for cold storage\",\"description\":\"Insulated sectional doors for cold storage are vertical-lifting panel doors built with 40 to 50 mm or thicker PU foam cores, thermal-broken frames, heated thresholds and cold-grade perimeter seals. They hold temperature zones from 0\u00b0C down to -45\u00b0C and limit air exchange during forklift traffic in chilled, freezer and deep-freeze facilities.\",\"url\":\"https:\/\/www.raxdoors.com\/blog\/insulated-sectional-cold-storage\/\"}\n<\/script><br \/>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What U-value should a cold storage sectional door target?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Chilled rooms work well near 0.33 to 0.46 W\/m\u00b2K. Freezers should demand a whole-door figure at or below the 0.30 to 0.46 caliber documented by cold storage vendors, with a thermal-broken frame.\"}},{\"@type\":\"Question\",\"name\":\"How thick should the panel be for a freezer?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For chilled stores, 40 to 50 mm of PU is standard on insulated sectional doors. For freezers at -18 to -25\u00b0C, industry quotes run 80 to 100 mm with closed-cell content above 95 percent and full thermal separation.\"}},{\"@type\":\"Question\",\"name\":\"Do I need floor heating under the door threshold?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"In rooms below freezing, yes at the perimeter. Frost heave can lift slabs by 2 to 3 inches, and an unheated sill ices over until the door no longer seals against it.\"}},{\"@type\":\"Question\",\"name\":\"Can one sectional door handle heavy forklift traffic?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Above roughly 50 cycles a day, open time dominates the energy bill. Keep the insulated sectional as the thermal wall and add a high-speed interior door to cut open time.\"}},{\"@type\":\"Question\",\"name\":\"Why does the vision panel frost over from the inside?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Single glazing sits below the dew point, so room moisture condenses and freezes on it. A heated double-pane vision panel keeps the inner glass above dew point and stays clear.\"}}]}\n<\/script><br \/>\n<script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"Article\",\"headline\":\"Insulated Sectional Doors for Cold Storage: A Buyer's Guide\",\"author\":{\"@type\":\"Organization\",\"name\":\"RAX Door Technology\"},\"publisher\":{\"@type\":\"Organization\",\"name\":\"RAX Door Technology\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/raxlogo-3.png\"}},\"datePublished\":\"2026-09-14\",\"dateModified\":\"2026-09-14\",\"image\":\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/09\/insulated-sectional-cold-storage-featured.webp\",\"mainEntityOfPage\":\"https:\/\/www.raxdoors.com\/blog\/insulated-sectional-cold-storage\/\"}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Fragen Sie einen Wartungsleiter nach einer Gefrierschrankt\u00fcr, und die Geschichte beginnt selten am Liefertag. Sie beginnt im zweiten Winter, wenn das Panel gut aussieht und die T\u00fcr sich immer noch nicht richtig schlie\u00dfen l\u00e4sst. Eis hat sich in der unteren F\u00fchrung angesammelt, die Dichtung ist mit dem Rahmen zugefroren, und ein Gabelstaplerfahrer klopft\/es frei vor jedem \u2026 <a title=\"Isolierte Sektionaltore f\u00fcr K\u00fchlh\u00e4user\" class=\"read-more\" href=\"https:\/\/www.raxdoors.com\/de\/blog\/insulated-sectional-cold-storage\/\" aria-label=\"Mehr Informationen \u00fcber isolierte Sektionaltore f\u00fcr K\u00fchlh\u00e4user\">Weiterlesen<\/a><\/p>","protected":false},"author":1,"featured_media":4246,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Cold Storage Sectional Doors: U-Value and Spec Guide","rank_math_description":"Buyer's guide to insulated sectional doors for cold storage: panel thickness by zone, thermal breaks, heated thresholds, cycle speed and compliance specs.","rank_math_focus_keyword":"insulated sectional doors for cold storage","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":""},"categories":[7],"tags":[],"class_list":["post-4255","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cold-room-doors"],"_links":{"self":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/4255","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/comments?post=4255"}],"version-history":[{"count":2,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/4255\/revisions"}],"predecessor-version":[{"id":4296,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/4255\/revisions\/4296"}],"wp:attachment":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/media?parent=4255"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/categories?post=4255"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/tags?post=4255"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}