{"id":2555,"date":"2026-08-24T14:46:27","date_gmt":"2026-08-24T06:46:27","guid":{"rendered":"https:\/\/www.raxdoors.com\/blog\/cold-room-sliding-door-smart-design\/"},"modified":"2026-08-30T00:40:18","modified_gmt":"2026-08-29T16:40:18","slug":"cold-room-sliding-door-smart-design","status":"publish","type":"post","link":"https:\/\/www.raxdoors.com\/de\/blog\/cold-room-sliding-door-smart-design\/","title":{"rendered":"K\u00e4lteraum-Schiebet\u00fcren: intelligentes Temperaturschutz-Design"},"content":{"rendered":"<p>Industrial cold storage doorways represent the most critical thermodynamic boundary in any refrigerated facility. Every time a doorway opens, cold dense air cascades outward along the floor while warm, moisture-laden ambient air rushes in across the top of the opening. This continuous convective air exchange introduces immense refrigeration loads, causes heavy frost buildup on evaporators, and risks severe temperature excursions for stored inventory.<\/p>\n<p>Traditional manual sliding doors often fail in high-throughput distribution environments. Heavy manual door leaves lead to operator fatigue, resulting in doors left propped open during busy loading shifts. Furthermore, flat sliding tracks and brittle rubber gaskets allow continuous air infiltration around door perimeters even when closed.<\/p>\n<p>Next-generation smart cold room sliding doors eliminate these thermodynamic vulnerabilities through kinematic precision engineering. By combining drop-and-slide gravity track geometry, multi-chamber co-extruded EPDM gaskets, smart PTC heated frame breaks, and automated brushless servo drives, these systems deliver uncompromising temperature protection.<\/p>\n<figure class=\"aligncenter\">\n  <img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-ul325-safety-sensor-beam.webp\" alt=\"Heavy duty automated cold storage sliding door installed on temperature controlled warehouse\" width=\"1200\" height=\"675\" loading=\"lazy\" \/><figcaption>Smart automated sliding doors seal large industrial apertures rapidly to preserve critical sub-zero thermal envelopes.<\/figcaption><\/figure>\n<h2 id=\"thermodynamic-physics-of-cold-room-sliding-door-apertures\">Why Cold Storage Doorways Lose So Much Cold Air<\/h2>\n<p>The thermodynamic forces acting across a cold room doorway are governed by air density differentials under <a href=\"https:\/\/www.ashrae.org\/technical-resources\/ashrae-handbook\" target=\"_blank\" rel=\"noopener noreferrer\">ASHRAE Refrigeration Handbook<\/a> principles. At -25\u00b0C, refrigerated air has a density of 1.39 kg\/m\u00b3, compared to 1.20 kg\/m\u00b3 for ambient air at +20\u00b0C.<\/p>\n<p>This substantial density gradient creates a natural chimney effect across open doorways:<\/p>\n<ul>\n<li><strong>Convective Infiltration Velocity:<\/strong> Cold dense air flows across the floor threshold at velocities up to 1.2 m\/s, pulling warm external air through the upper half of the aperture.<\/li>\n<li><strong>Latent Energy Load Spikes:<\/strong> Open doorways introduce <strong>15 to 25 kW of latent refrigeration load per minute<\/strong> of open exposure.<\/li>\n<li><strong>Moisture Condensation and Frost:<\/strong> Water vapor carried by incoming warm air immediately condenses upon contacting sub-zero wall panels and evaporators, forming thick frost layers that degrade refrigeration efficiency.<\/li>\n<\/ul>\n<p>Minimizing total open duration and ensuring an airtight perimeter seal when closed are the two primary requirements for protecting facility energy efficiency.<\/p>\n<figure class=\"aligncenter\">\n  <img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-reduction-worm-gearbox-lock.webp\" alt=\"Drop and slide track mechanism for heavy duty cold room door hermetic sealing\" width=\"1200\" height=\"675\" loading=\"lazy\" \/><figcaption>The 45-degree drop-and-slide track geometry lowers and compresses the door leaf securely against the frame.<\/figcaption><\/figure>\n<h2 id=\"drop-and-slide-gravity-track-geometry-achieving-hermetic-compression\">How Drop-and-Slide Tracks Create an Airtight Seal<\/h2>\n<p>The cornerstone of modern cold room sliding door engineering is the <strong>Drop-and-Slide<\/strong> kinematic track rail system governed by <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/4efba9b1-2db6-4447-9759-dd3e88dc65b5\/en-12426-2000\" target=\"_blank\" rel=\"noopener noreferrer\">EN 12426 air permeability standards<\/a>. Unlike flat tracks where gaskets drag along surfaces, drop-and-slide tracks isolate lateral travel from gasket compression.<\/p>\n<p>The system operates through an engineered dual-motion sequence:<\/p>\n<ol>\n<li><strong>Frictionless Lateral Travel:<\/strong> During horizontal opening and closing, heavy-duty Delrin rollers travel along an overhead extruded aluminum track. The door leaf remains suspended 10mm away from the wall and 15mm above the floor, completely eliminating gasket friction and wear.<\/li>\n<li><strong>Compound Drop-and-Inward Sealing:<\/strong> In the final 100mm of closing travel, the track features angled 45\u00b0 ramps. Gravitational force guides the rollers down these ramps, dropping the door leaf <strong>15mm vertically and 10mm inwardly<\/strong> against the frame.<\/li>\n<li><strong>Hermetic Gasket Compression:<\/strong> The weight of the door leaf (often 120 kg to 350 kg) is converted into over <strong>80 kg of continuous inward mechanical compression<\/strong>, sealing the perimeter airtight.<\/li>\n<\/ol>\n<p>When opened, the initial motion lifts the door leaf up and away from the jambs, allowing effortless manual or motorized travel without dragging.<\/p>\n<h2 id=\"multi-chamber-epdm-gaskets-and-ingress-defense-mechanics\">Multi-Chamber EPDM Gaskets &amp; Ingress Defense Mechanics<\/h2>\n<p>Gasket performance defines the long-term airtightness of <a href=\"https:\/\/www.raxdoors.com\/blog\/cold-room-door-types-differences\/\">cold room door assemblies<\/a>. Smart sliding doors utilize co-extruded multi-chamber EPDM (Ethylene Propylene Diene Monomer) synthetic sponge rubber formulated to maintain elasticity down to -45\u00b0C.<\/p>\n<p>The gasket profile incorporates three functional zones:<\/p>\n<ul>\n<li><strong>Dual Internal Air Dampening Chambers:<\/strong> Sealed internal hollow cores provide thermal dampening and absorb compression forces without permanent deformation.<\/li>\n<li><strong>Triple Outer Sealing Wipers:<\/strong> Multiple exterior wiper lips create a tiered pressure barrier that blocks high-velocity air infiltration.<\/li>\n<li><strong>Rigid Mounting Foot:<\/strong> A high-durometer base locks securely into an aluminum retaining channel, allowing rapid replacement without adhesives.<\/li>\n<\/ul>\n<p>This engineered profile achieves Class 4 airtightness ratings, preventing air leakage even during atmospheric pressure fluctuations caused by forklift traffic.<\/p>\n<h2 id=\"cold-room-sliding-door-engineering-specifications-matrix\">Comparing Sliding Door Specs for Chillers and Freezers<\/h2>\n<p>The following engineering comparison matrix evaluates smart sliding door configurations across operating temperatures and facility requirements:<\/p>\n<table class=\"wp-block-table\">\n<thead>\n<tr>\n<th>Door Configuration<\/th>\n<th>Operating Temperature<\/th>\n<th>Core Thickness (PIR)<\/th>\n<th>Thermal Transmittance U<\/th>\n<th>Max Opening Speed<\/th>\n<th>Frame Heating Specification<\/th>\n<th>Airtightness Class<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Medium-Duty Chiller Sliding<\/strong><\/td>\n<td>0\u00b0C to +10\u00b0C<\/td>\n<td>80 mm<\/td>\n<td>0.26 W\/(m\u00b2\u00b7K)<\/td>\n<td>1.0 m\/s (Optional)<\/td>\n<td>Unheated \/ Optional 20 W\/m<\/td>\n<td>EN 12426 Class 3<\/td>\n<\/tr>\n<tr>\n<td><strong>Heavy-Duty Freezer Sliding<\/strong><\/td>\n<td>-10\u00b0C to -28\u00b0C<\/td>\n<td>120 mm<\/td>\n<td><strong>0.18 W\/(m\u00b2\u00b7K)<\/strong><\/td>\n<td>1.5 m\/s (Automated)<\/td>\n<td><strong>35 W\/m PTC Self-Regulating<\/strong><\/td>\n<td><strong>EN 12426 Class 4<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Deep-Freeze &amp; Blast Freezer<\/strong><\/td>\n<td>-28\u00b0C to -45\u00b0C<\/td>\n<td><strong>150 mm (VIP Hybrid)<\/strong><\/td>\n<td><strong>0.12 W\/(m\u00b2\u00b7K)<\/strong><\/td>\n<td>1.8 m\/s (High-Speed)<\/td>\n<td><strong>45 W\/m Dual Frame + Threshold<\/strong><\/td>\n<td><strong>EN 12426 Class 4<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Gas-Tight Controlled Atmosphere<\/strong><\/td>\n<td>0\u00b0C to +4\u00b0C (Fruit storage)<\/td>\n<td>100 mm<\/td>\n<td>0.21 W\/(m\u00b2\u00b7K)<\/td>\n<td>Manual (Cam-lock)<\/td>\n<td>Unheated<\/td>\n<td><strong>Hermetic (0.00 m\u00b3\/h\u00b7m\u00b2)<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Specifying the proper door thickness and heating capacity ensures optimal energy performance when paired with <a href=\"https:\/\/www.raxdoors.com\/blog\/cold-room-panel-thickness-guide\/\">insulated wall panels<\/a> and proper structural framing.<\/p>\n<h2 id=\"integrated-thermal-breaks-and-smart-ptc-frame-de-icing-cables\">Integrated Thermal Breaks &amp; Smart PTC Frame De-Icing Cables<\/h2>\n<p>In sub-zero freezer applications, door frame thermal bridging causes condensation to freeze on perimeter surfaces. This ice welds rubber gaskets to the frame, causing gaskets to tear when the door opens.<\/p>\n<p>Smart cold room sliding doors solve this challenge through a dual-defense thermal break system governed by <a href=\"https:\/\/www.iso.org\/standard\/65207.html\" target=\"_blank\" rel=\"noopener noreferrer\">EN ISO 10077 standards<\/a>:<\/p>\n<h3 id=\"polyamide-structural-thermal-breaks\">Polyamide Structural Thermal Breaks<\/h3>\n<p>Extruded aluminum door frames incorporate 24mm continuous polyamide (PA66 GF25) insulating struts. These thermal breaks isolate external warm-side metal from interior sub-zero surfaces, reducing frame thermal conductivity by 90%.<\/p>\n<h3 id=\"self-regulating-ptc-heating-elements\">Self-Regulating PTC Heating Elements<\/h3>\n<p>Integrated internal channels house self-regulating Positive Temperature Coefficient (PTC) heating cables delivering <strong>35 to 45 W\/m at 230V<\/strong>. PTC cables automatically modulate heat output based on ambient temperature, maintaining frame surfaces at +5\u00b0C without energy waste.<\/p>\n<p>In blast freezers, a matching heated threshold plate embedded flush with the concrete floor prevents ice damming beneath bottom wiper gaskets.<\/p>\n<div class=\"cta-box\" style=\"background:#1e293b; color:#ffffff; padding:28px; border-radius:8px; margin:36px 0; text-align:center;\">\n<h3 style=\"color:#ffffff; margin-top:0; font-size:22px;\">Engineered Cold Storage Sliding Doors for Maximum Energy Efficiency<\/h3>\n<p style=\"color:#cbd5e1; font-size:15px; max-width:640px; margin:0 auto 20px auto;\">Protect critical freezer temperatures and slash refrigeration energy waste with RAXDOOR&#8217;s automated drop-and-slide cold room door solutions.<\/p>\n<p>  <a href=\"https:\/\/www.raxdoors.com\/clean-room-doors\/hermetic-sliding-door\/\" style=\"background:#e11d48; color:#ffffff; padding:12px 28px; border-radius:6px; font-weight:bold; text-decoration:none; display:inline-block;\">Explore RAXDOOR Cold Storage Solutions<\/a>\n<\/div>\n<h2 id=\"smart-automated-motion-control-brushless-inverters-and-radar-activation\">Smart Automated Motion Control: Brushless Inverters &amp; Radar Activation<\/h2>\n<p>Automation transforms a passive insulated door into an active energy barrier. Modern cold room sliding doors utilize microprocessor-controlled synchronous brushless DC servo motors operating under <a href=\"https:\/\/standards.iteh.ai\/catalog\/standards\/cen\/e6a5ea97-9e46-4c74-8aa4-cfc8153c9e6c\/en-12453-2017-a1-2021\" target=\"_blank\" rel=\"noopener noreferrer\">EN 12453 functional safety standards<\/a>.<\/p>\n<p>Automated motion control delivers key operational advantages:<\/p>\n<ul>\n<li><strong>Rapid Open-Close Cycles:<\/strong> Operating speeds up to <strong>1.8 m\/s<\/strong> reduce total doorway exposure time by <strong>65%<\/strong> compared to manual sliding doors.<\/li>\n<li><strong>Intelligent Microwave Radar:<\/strong> Overhead Doppler radar sensors differentiate between cross-traffic pedestrians and approaching forklift trucks, opening the door only when necessary.<\/li>\n<li><strong>Integrated Safety Light Curtains:<\/strong> Multi-beam optical safety grids monitor the entire doorway aperture, reversing door travel instantly if an obstruction is detected without requiring physical contact.<\/li>\n<li><strong>BMS Telemetry Integration:<\/strong> Integrated controllers log door cycle counts, open durations, and temperature alarms directly to facility Building Management Systems.<\/li>\n<\/ul>\n<figure class=\"aligncenter\">\n  <img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-ac-vs-bldc-motor-electromechanics.webp\" alt=\"Automated cold room sliding door equipped with microwave radar sensor and optical safety edge\" width=\"1200\" height=\"675\" loading=\"lazy\" \/><figcaption>Overhead radar activation and infrared safety sensors ensure rapid doorway cycling and safe forklift passage.<\/figcaption><\/figure>\n<h2 id=\"preventative-maintenance-sop-for-100-percent-thermal-envelope-integrity\">Monthly Maintenance SOP to Ensure Reliable Operation<\/h2>\n<p>To ensure long-term reliability and airtight performance, facility maintenance teams should execute this monthly inspection routine:<\/p>\n<ol>\n<li><strong>Track and Roller Cleaning:<\/strong> Clear debris from overhead track rails and inspect Delrin rollers for flat spots or bearing play.<\/li>\n<li><strong>Roller Bearing Lubrication:<\/strong> Apply food-grade synthetic grease (USDA H1 approved) formulated to maintain viscosity down to -40\u00b0C.<\/li>\n<li><strong>Gasket Inspection and Conditioning:<\/strong> Wipe EPDM perimeter seals with food-grade silicone lubricant to preserve flexibility and prevent ozone cracking.<\/li>\n<li><strong>Heater Circuit Continuity Testing:<\/strong> Measure PTC heater cable resistance using a digital multimeter to ensure proper current draw (target insulation resistance &gt; 50 M\u03a9).<\/li>\n<li><strong>Optical Safety Sensor Calibration:<\/strong> Test safety light curtains and bottom edge sensors to verify immediate reverse operation upon beam interruption.<\/li>\n<\/ol>\n<figure class=\"aligncenter\">\n  <img decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-drive-transmission-types.webp\" alt=\"Electric servo drive motor and control system powering automated cold room sliding door\" width=\"1200\" height=\"675\" loading=\"lazy\" \/><figcaption>Industrial brushless servo drives deliver smooth acceleration and decelerated soft-stop closing cycles.<\/figcaption><\/figure>\n<div class=\"consultation-note\" style=\"background:#f8fafc; border-left:4px solid #64748b; padding:20px 24px; margin:32px 0;\">\n<h4 style=\"margin-top:0; color:#1e293b; font-size:16px;\">Engineering Field Advisory<\/h4>\n<p style=\"margin-bottom:0; color:#475569; font-size:14px;\">Never use petroleum-based lubricants or aggressive solvent cleaners on EPDM cold room door gaskets. Petroleum compounds cause rapid swelling, loss of elasticity, and premature gasket failure within sub-zero operating environments.<\/p>\n<\/div>\n<h2 id=\"frequently-asked-questions\">Frequently Asked Questions<\/h2>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">How does a drop-and-slide door achieve a hermetic seal?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Angled track ramps guide the door 15mm downward and 10mm inward during the final closing travel, compressing multi-chamber EPDM gaskets with over 80 kg of force.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">Why do freezer sliding doors require frame heaters?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Frame heaters maintain perimeter surface temperatures at +5\u00b0C, preventing condensation from freezing and welding rubber gaskets to the frame.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">What is the recommended opening speed for automated cold room doors?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Automated cold room doors should open at 1.2 to 1.8 m\/s to allow rapid forklift transit while reducing open-door convective air infiltration by 65%.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">Can sliding cold room doors be used for controlled atmosphere rooms?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Yes. Gas-tight sliding doors with inflatable or heavy-compression mechanical gaskets achieve complete hermetic sealing for oxygen-controlled fruit storage.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">How often should cold storage door gaskets be inspected?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Gaskets should be inspected monthly for cracks and lubricated with food-grade silicone grease to maintain elasticity at temperatures down to -45\u00b0C.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does a drop-and-slide door achieve a hermetic seal?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Angled track ramps guide the door 15mm downward and 10mm inward during the final closing travel, compressing multi-chamber EPDM gaskets with over 80 kg of force.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why do freezer sliding doors require frame heaters?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Frame heaters maintain perimeter surface temperatures at +5\u00b0C, preventing condensation from freezing and welding rubber gaskets to the frame.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the recommended opening speed for automated cold room doors?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Automated cold room doors should open at 1.2 to 1.8 m\/s to allow rapid forklift transit while reducing open-door convective air infiltration by 65%.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can sliding cold room doors be used for controlled atmosphere rooms?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Gas-tight sliding doors with inflatable or heavy-compression mechanical gaskets achieve complete hermetic sealing for oxygen-controlled fruit storage.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How often should cold storage door gaskets be inspected?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Gaskets should be inspected monthly for cracks and lubricated with food-grade silicone grease to maintain elasticity at temperatures down to -45\u00b0C.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Industrielle K\u00e4lteraum-Durchg\u00e4nge stellen die kritischste thermodynamische Grenze in jeder K\u00fchlanlage dar. Jedes Mal, wenn ein Durchgang ge\u00f6ffnet wird, str\u00f6mt kalte, dichte Luft am Boden nach au\u00dfen, w\u00e4hrend warme, feuchtigkeitsbeladene Umgebungsluft oben \u00fcber der \u00d6ffnung einstr\u00f6mt. Dieser kontinuierliche konvektive Luftaustausch verursacht enorme K\u00e4ltebelastungen, f\u00fchrt zu starkem Frostaufbau an Verdampfern, \u2026 <a title=\"K\u00e4lteraum-Schiebet\u00fcren: intelligentes Temperaturschutz-Design\" class=\"read-more\" href=\"https:\/\/www.raxdoors.com\/de\/blog\/cold-room-sliding-door-smart-design\/\" aria-label=\"Mehr Informationen \u00fcber K\u00e4lteraum-Schiebet\u00fcren: Intelligentes Temperaturschutzdesign\">Weiterlesen<\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Cold Room Sliding Door: Smart Temperature Design","rank_math_description":"Discover how smart cold room sliding doors protect temperatures: drop-and-slide tracks, multi-chamber EPDM seals, PTC frame heaters, and automated radar.","rank_math_focus_keyword":"Cold Room Sliding Door Protects Temperature With Smart Design","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":""},"categories":[1],"tags":[],"class_list":["post-2555","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/2555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/comments?post=2555"}],"version-history":[{"count":8,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/2555\/revisions"}],"predecessor-version":[{"id":3015,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/2555\/revisions\/3015"}],"wp:attachment":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/media?parent=2555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/categories?post=2555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/tags?post=2555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}