{"id":2542,"date":"2026-08-24T14:02:14","date_gmt":"2026-08-24T06:02:14","guid":{"rendered":"https:\/\/www.raxdoors.com\/blog\/cold-room-door-external-elements\/"},"modified":"2026-08-30T00:39:58","modified_gmt":"2026-08-29T16:39:58","slug":"cold-room-door-external-elements","status":"publish","type":"post","link":"https:\/\/www.raxdoors.com\/de\/blog\/cold-room-door-external-elements\/","title":{"rendered":"Externe Elemente einer K\u00e4lteraumt\u00fcr: Teile und Funktionen"},"content":{"rendered":"<p>A cold storage door is an active mechanical pressure and thermal boundary. While the internal polyurethane foam core provides passive thermal insulation, the external elements deliver structural integrity, mechanical motion, and airtight perimeter sealing. When any external hardware component fails, thermal leakage surges rapidly, causing ice accumulation and severe compressor strain.<\/p>\n<p>From structural anodized aluminum frames to rising-cam hinges, heavy-duty latch handles, and self-regulating perimeter heating circuits, each external component performs a critical role. Understanding the engineering anatomy and kinematic operation of these external elements enables facility managers to specify, operate, and maintain cold storage facilities efficiently.<\/p>\n<figure class=\"aligncenter\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-six-stage-action-sequence.webp\" alt=\"Heavy duty cold storage door showing external hinges, latch handle, and aluminum frame\" width=\"1200\" height=\"675\" \/><figcaption>External hardware components engineered to maintain hermetic sealing under severe thermal differentials.<\/figcaption><\/figure>\n<h2 id=\"what-are-the-external-elements-of-a-cold-room-door\">What Are the External Elements of a Cold Room Door?<\/h2>\n<p>The external elements of a cold storage door comprise all mechanical, structural, electrical, and sealing components mounted to the outer envelope of the insulated door blade and perimeter wall cutout. These components experience continuous mechanical cycling, heavy physical impacts, and severe thermal gradients between ambient warehouse environments and sub-zero storage rooms.<\/p>\n<p>The primary external elements can be categorized into six core functional systems:<\/p>\n<table class=\"wp-block-table\">\n<thead>\n<tr>\n<th>External Component<\/th>\n<th>Material Engineering<\/th>\n<th>Primary Kinematic &amp; Thermal Function<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Perimeter Frame &amp; Counterframe<\/strong><\/td>\n<td>Extruded 6063-T6 aluminum with continuous polyamide thermal breaks<\/td>\n<td>Encases wall panel cutout; isolates exterior aluminum from sub-zero internal frame<\/td>\n<\/tr>\n<tr>\n<td><strong>Rising-Cam Hinges (Hinged Doors)<\/strong><\/td>\n<td>High-pressure diecast composite alloy \/ 304 stainless steel with Delrin cams<\/td>\n<td>Lifts door blade 8mm during opening arc; eliminates floor sweep friction and wear<\/td>\n<\/tr>\n<tr>\n<td><strong>Drop-Down Suspension Track (Sliding)<\/strong><\/td>\n<td>Extruded aluminum rail with 45-degree drop recesses and nylon roller trolleys<\/td>\n<td>Guides horizontal travel and drives door 10mm downward and 8mm inward upon closure<\/td>\n<\/tr>\n<tr>\n<td><strong>Ergonomic Latch &amp; Lock Mechanism<\/strong><\/td>\n<td>High-impact composite nylon housing with 304 stainless steel internal latch bolts<\/td>\n<td>Compresses perimeter gaskets; incorporates keyed Euro-cylinder and emergency release<\/td>\n<\/tr>\n<tr>\n<td><strong>Perimeter Sealing Gaskets<\/strong><\/td>\n<td>Co-extruded dual-durometer EPDM rubber (Shore A 70 base + Shore A 50 bulb)<\/td>\n<td>Provides continuous airtight and vapor-tight seal around 100% of the door perimeter<\/td>\n<\/tr>\n<tr>\n<td><strong>Frame &amp; Threshold Heating Loop<\/strong><\/td>\n<td>Self-regulating low-voltage electric trace cable (25W\/m to 35W\/m)<\/td>\n<td>Maintains contact surfaces above freezing, preventing ice bridges and gasket tearing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Each external component must withstand severe operational stresses. In cold storage distribution hubs, exterior door elements endure over 200 opening cycles daily. Choosing inferior hardware leads to premature mechanical sagging, gasket degradation, air infiltration, and catastrophic refrigeration energy waste.<\/p>\n<figure class=\"aligncenter\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-counterbalance-physics-load-vector-1.webp\" alt=\"Cross section of cold room door frame showing integrated polyamide thermal break\" width=\"1200\" height=\"675\" \/><figcaption>Integrated polyamide thermal breaks eliminate conductive heat transfer through aluminum frames.<\/figcaption><\/figure>\n<h2 id=\"structural-thermal-frames-and-pvc-break-profiles\">Why Cold Room Door Frames Need Thermal Breaks<\/h2>\n<p>The perimeter door frame serves as the structural foundation for the entire door assembly. It reinforces the sandwich wall panel cutout while providing rigid mounting anchors for heavy hinges, latch strikes, and overhead suspension tracks.<\/p>\n<p>In standard building doors, metal frames act as thermal bridges. Aluminum exhibits a high thermal conductivity of approximately 205 W\/m\u00b7K. If a solid aluminum frame penetrates from a +25\u00b0C warehouse into a -25\u00b0C blast freezer, conductive heat transfer causes massive refrigeration loss. Moisture condenses on the warm exterior frame face, creating heavy puddles and frost buildup.<\/p>\n<p>Industrial cold storage frames solve this challenge using co-extruded <strong>Thermal Break Profiles<\/strong>. The exterior aluminum profile is physically decoupled from the interior counterframe by a rigid polyamide or PVC insulating bridge. Polyamide exhibits a thermal conductivity of less than 0.25 W\/m\u00b7K, reducing conductive heat transfer by over 99%.<\/p>\n<p>The frame assembly incorporates internal wiring raceways. These hollow extrusions conceal electric heating cables, grounding wires, and magnetic door status sensors. Mounting fasteners are installed with non-conductive nylon thermal isolation sleeves to prevent metallic through-bolt thermal bridging.<\/p>\n<h2 id=\"heavy-duty-hinges-rise-mechanisms-and-drop-tracks\">Hinges and Track Rails: How Cold Room Doors Open and Seal<\/h2>\n<p>Door suspension hardware carries the entire weight of the insulated door blade (frequently exceeding 150 kg) while delivering precise closing geometry.<\/p>\n<h3 id=\"rising-cam-hinge-mechanics\">Rising-Cam Hinge Kinematics (Hinged Doors)<\/h3>\n<p>Standard architectural butt hinges swing on a flat horizontal plane. When installed on thick cold room doors with bottom wiper gaskets, flat-swinging hinges cause the rubber sweep to drag across the floor throughout the entire 180-degree opening arc. This continuous friction shreds the rubber sweep and scratches floor finishes.<\/p>\n<p>Industrial cold room doors utilize <strong>Rising-Cam Hinges<\/strong> equipped with internal helical ramps manufactured from self-lubricating Delrin polymer. As the door opens, the internal cam forces the door blade to rise 8mm vertically within the first 30 degrees of opening rotation. This vertical lift raises the bottom wiper gasket clear off the floor, eliminating friction and wear.<\/p>\n<p>When the door is pushed closed, gravity drives the helical cam down the ramp. This downward slope pulls the door leaf downward and inward, compressing perimeter gaskets tightly against the frame face without requiring excessive manual pushing force.<\/p>\n<h3 id=\"drop-down-sliding-track-dynamics\">Drop-Down Sliding Track Dynamics (Sliding Doors)<\/h3>\n<p>Heavy sliding cold storage doors employ overhead aluminum guide tracks equipped with dual-bearing nylon roller trolleys. To achieve hermetic sealing without causing rolling friction during travel, the track profile features precision-machined 45-degree drop recesses at the closed position.<\/p>\n<p>During horizontal travel, the door blade remains elevated 10mm above the floor and 8mm away from the frame face. As the door reaches full closure, the trolley wheels descend into the drop recesses. This dual-axis motion drives the door leaf simultaneously downward and inward, compressing top, side, and bottom gaskets firmly against the frame.<\/p>\n<figure class=\"aligncenter\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-emergency-release-balance-test.webp\" alt=\"Heavy duty rising cam cold room door hinge with 3D adjustment screws\" width=\"1200\" height=\"675\" \/><figcaption>Rising-cam hinges lift the door blade 8mm during opening, protecting bottom sweep gaskets.<\/figcaption><\/figure>\n<h2 id=\"external-ergonomic-lever-handles-and-locking-cylinders\">External Ergonomic Lever Handles and Locking Cylinders<\/h2>\n<p>Cold room door latches must generate strong mechanical leverage to overcome gasket compression resistance upon opening and closing.<\/p>\n<p>Industrial external latch handles utilize high-tensile composite nylon housings paired with internal 304 stainless steel latch bolts. The extended ergonomic lever provides a high mechanical advantage ratio. An operator applying only 40 Newtons of hand force generates over 350 Newtons of perimeter gasket pull-in force upon latching.<\/p>\n<p>External handles incorporate keyed Euro-profile brass lock cylinders for security. Standard commercial padlocks risk freezing solid due to moisture condensation. Industrial cold room handles feature heated lock housings or water-shedding protective rubber boots to ensure lock reliability in damp environments.<\/p>\n<p>Crucially, all external latch mechanisms link directly to an internal <strong>Emergency Safety Push-Rod<\/strong>. Under OSHA and EN 179 safety regulations, pressing the internal luminous emergency knob overrides and disengages the exterior latch instantly, ensuring trapped workers escape safely even if the exterior handle is padlocked.<\/p>\n<div class=\"cta-box\" style=\"background:#1e293b; color:#ffffff; padding:28px; border-radius:8px; margin:36px 0; text-align:center;\">\n<h3 style=\"color:#ffffff; margin-top:0; font-size:22px;\">Industrial Cold Storage Doors with Heavy-Duty Hardware<\/h3>\n<p style=\"color:#cbd5e1; font-size:15px; max-width:640px; margin:0 auto 20px auto;\">Need rugged cold storage doors equipped with corrosion-resistant 304 stainless steel hardware, rising-cam hinges, and integrated frame heating? Discover RAXDOOR&#8217;s engineered thermal door systems built for extreme durability.<\/p>\n<p>  <a href=\"https:\/\/www.raxdoors.com\/high-speed-doors\/insulated-high-speed-door\/\" style=\"background:#e11d48; color:#ffffff; padding:12px 28px; border-radius:6px; font-weight:bold; text-decoration:none; display:inline-block;\">Explore RAXDOOR Cold Storage Solutions<\/a>\n<\/div>\n<h2 id=\"perimeter-sealing-gaskets-and-bottom-wiper-sweeps\">Perimeter Sealing Gaskets and Bottom Wiper Sweeps<\/h2>\n<p>The perimeter gasket is the flexible contact element responsible for preventing convective mass air exchange. A standard cold room door utilizes two distinct gasket geometries:<\/p>\n<h3 id=\"epdm-bulb-compression-gaskets\">EPDM Bulb Compression Gaskets (Top &amp; Side Jambs)<\/h3>\n<p>The top header and side jambs feature continuous co-extruded dual-durometer EPDM rubber profiles. The base spine consists of rigid Shore A 70 rubber that locks securely into the aluminum door retention channel. The sealing bulb consists of soft, resilient Shore A 50 rubber with high elastic memory.<\/p>\n<p>When compressed by 4.0mm to 5.0mm (approximately 30% to 35% deflection), the hollow EPDM bulb forms a continuous airtight seal. EPDM maintains high flexibility down to -40\u00b0C, resisting ozone cracking, UV degradation, and chemical washdowns.<\/p>\n<h3 id=\"heavy-duty-chloroprene-bottom-sweeps\">Heavy-Duty Chloroprene Bottom Sweeps (Floor Threshold)<\/h3>\n<p>Because floor surfaces experience heavy forklift wheel wear and micro-unevenness, bottom threshold sealing requires a dynamic multi-lip wiper profile. Bottom sweeps utilize reinforced chloroprene or thermoplastic elastomer (TPE) multi-fin wipers.<\/p>\n<p>The flexible triple-lip wiper deflects against the floor threshold during the final closing drop motion. This creates three independent air chambers that prevent cold air from cascading out along the floor.<\/p>\n<figure class=\"aligncenter\">\n  <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.raxdoors.com\/wp-content\/uploads\/2026\/08\/how-does-a-garage-door-opener-work-rotary-optical-travel-encoder.webp\" alt=\"Dual durometer EPDM perimeter gasket and multi-lip bottom sweep profile\" width=\"1200\" height=\"675\" \/><figcaption>Dual-durometer EPDM gaskets deliver uniform 35% compression without permanent rubber deformation.<\/figcaption><\/figure>\n<h2 id=\"freeze-protection-heating-cables-and-terminal-junctions\">Freeze-Protection Heating Cables and Terminal Junctions<\/h2>\n<p>In sub-zero freezer applications operating between -18\u00b0C and -35\u00b0C, airborne moisture condenses at the thermal boundary between warm warehouse air and cold door surfaces. Without external heating, this condensation freezes into solid ice bridges, cementing the rubber gasket to the metal frame.<\/p>\n<p>When workers attempt to force open an ice-locked door, the frozen gasket tears away from the door blade, destroying the thermal seal. To prevent this failure, freezer door frames incorporate continuous <strong>Electric Trace Heating Loops<\/strong>.<\/p>\n<p>Heating cables are installed in dedicated extruded channels directly beneath the perimeter gasket contact face and inside the floor threshold. These self-regulating heating elements deliver 25W to 35W per linear meter, maintaining contact surfaces at +3\u00b0C to +5\u00b0C.<\/p>\n<p>The heating circuit connects to an exterior IP65-rated moisture-proof terminal junction box. High-reliability installations incorporate dual-circuit heating loops (primary operating cable plus a built-in redundant backup cable), allowing instant switchover during heating element failure without requiring frame disassembly.<\/p>\n<h2 id=\"preventative-inspection-and-external-element-maintenance\">Preventative Inspection and External Element Maintenance<\/h2>\n<p>Routine preventative inspection of external cold room door elements prevents costly refrigeration breakdowns and extends hardware service life:<\/p>\n<ul>\n<li><strong>Monthly Gasket Inspection:<\/strong> Inspect EPDM bulbs for tears, cracking, and loss of elastic rebound. Clean rubber profiles using warm water and neutral detergent to remove grease and food residues.<\/li>\n<li><strong>Quarterly Hinge &amp; Track Fastener Torque:<\/strong> Check mounting bolt torque on hinges, latch strikes, and overhead track brackets. Retorque all anchor bolts to 18 Nm using a calibrated torque wrench.<\/li>\n<li><strong>90-Day Low-Temperature Lubrication:<\/strong> Apply food-grade synthetic low-temperature silicone grease to rising-cam ramps, nylon trolley bearings, and internal latch pivot pins. Never use hydrocarbon-based oils, which degrade EPDM rubber.<\/li>\n<li><strong>Heater Circuit Resistance Audit:<\/strong> Measure heating cable electrical resistance semi-annually with a multimeter to verify unbroken trace continuity and correct wattage output.<\/li>\n<\/ul>\n<div class=\"consultation-note\" style=\"background:#f8fafc; border-left:4px solid #64748b; padding:20px 24px; margin:32px 0;\">\n<h4 style=\"margin-top:0; color:#1e293b; font-size:16px;\">Engineering Field Advisory<\/h4>\n<p style=\"margin-bottom:0; color:#475569; font-size:14px;\">In blast freezer applications operating below -25\u00b0C, always install dual-circuit heating cables with an external selector switch. Gasket ice adhesion occurs in under 20 minutes if heating power fails, causing immediate door jamming and severe inventory risk.<\/p>\n<\/div>\n<h2 id=\"frequently-asked-questions\">Frequently Asked Questions<\/h2>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">How does a rising-cam hinge protect cold room door bottom gaskets?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">The internal helical cam lifts the door blade 8mm vertically as the door swings open. This lifts the bottom rubber wiper off the floor, preventing friction, tearing, and floor scuffing during the opening arc.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">What is the purpose of a thermal break in a cold room door frame?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">A thermal break is a continuous polyamide insulating profile separating the exterior and interior aluminum frame extrusions. It stops conductive heat transfer, eliminating exterior condensation sweating and frost buildup.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">Why do freezer doors require perimeter electrical heating cables?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Heating cables maintain frame contact surfaces at +3\u00b0C, preventing condensation from freezing into ice. Without heating, ice cements the rubber gasket to the frame, tearing the gasket upon opening.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">How can workers escape if a cold room door is locked from the outside?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Cold storage doors feature an internal luminous emergency push-rod. Pressing this glowing internal knob mechanically overrides and disengages the exterior latch, allowing instant escape even if padlocked.<\/p>\n<\/div>\n<div class=\"faq-card\" style=\"background:#f9f9f9; border-left:4px solid #2563eb; border-radius:4px; padding:24px; margin-bottom:20px;\">\n<h3 style=\"margin-top:0; font-size:18px; color:#1e293b;\">What lubricant should be used on cold storage door hinges and tracks?<\/h3>\n<p style=\"margin-bottom:0; color:#475569;\">Always use certified food-grade, low-temperature synthetic silicone grease. Avoid petroleum-based lubricants or standard grease, which become gummy below zero and chemically degrade EPDM rubber gaskets.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does a rising-cam hinge protect cold room door bottom gaskets?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The internal helical cam lifts the door blade 8mm vertically as the door swings open. This lifts the bottom rubber wiper off the floor, preventing friction, tearing, and floor scuffing during the opening arc.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the purpose of a thermal break in a cold room door frame?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A thermal break is a continuous polyamide insulating profile separating the exterior and interior aluminum frame extrusions. It stops conductive heat transfer, eliminating exterior condensation sweating and frost buildup.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Why do freezer doors require perimeter electrical heating cables?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Heating cables maintain frame contact surfaces at +3\u00b0C, preventing condensation from freezing into ice. Without heating, ice cements the rubber gasket to the frame, tearing the gasket upon opening.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can workers escape if a cold room door is locked from the outside?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Cold storage doors feature an internal luminous emergency push-rod. Pressing this glowing internal knob mechanically overrides and disengages the exterior latch, allowing instant escape even if padlocked.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What lubricant should be used on cold storage door hinges and tracks?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Always use certified food-grade, low-temperature synthetic silicone grease. Avoid petroleum-based lubricants or standard grease, which become gummy below zero and chemically degrade EPDM rubber gaskets.\"\n      }\n    }\n  ]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Eine K\u00e4lteraumt\u00fcr ist eine aktive mechanische Druck- und W\u00e4rmebarriere. W\u00e4hrend der interne Polyurethan-Schaumkern eine passive W\u00e4rmed\u00e4mmung bietet, \u00fcbernehmen die externen Elemente strukturelle Integrit\u00e4t, mechanische Bewegung und eine luftdichte Perimeterdichtung. Wenn eine externe Hardwarekomponente ausf\u00e4llt, steigt die thermische Durchl\u00e4ssigkeit schnell an, was zu Eisbildung und erheblicher Verdichterbela\u0441\u0442ung f\u00fchrt. Aus strukturellem eloxiertem Aluminium \u2026 <a title=\"Externe Elemente einer K\u00e4lteraumt\u00fcr: Teile und Funktionen\" class=\"read-more\" href=\"https:\/\/www.raxdoors.com\/de\/blog\/cold-room-door-external-elements\/\" aria-label=\"Mehr Informationen \u00fcber Externe Elemente einer K\u00e4lterraumt\u00fcr: Teile und Funktionen\">Weiterlesen<\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","rank_math_title":"Cold Room Door External Elements: Parts & Functions","rank_math_description":"Explore external elements of cold room doors: drop-and-slide tracks, insulated handles, safety release locks, frame heaters, and BMS sensors.","rank_math_focus_keyword":"External Elements of a Cold Room Door","rank_math_robots":"","rank_math_canonical_url":"","rank_math_facebook_title":"","rank_math_facebook_description":"","rank_math_twitter_title":"","rank_math_twitter_description":"","_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","_yoast_wpseo_focuskw":"","_yoast_wpseo_canonical":"","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_aioseo_title":"","_aioseo_description":"","_aioseo_keywords":"","_aioseo_robots_default":"","_aioseo_robots_noindex":"","_aioseo_og_title":"","_aioseo_og_description":"","_aioseo_twitter_title":"","_aioseo_twitter_description":"","aiosp_title":"","aiosp_description":"","aiosp_keywords":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_analysis_target_kw":"","_seopress_robots_canonical":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_genesis_title":"","_genesis_description":"","_genesis_canonical":"","_genesis_noindex":"","_genesis_nofollow":"","slim_seo":""},"categories":[1],"tags":[],"class_list":["post-2542","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/2542","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/comments?post=2542"}],"version-history":[{"count":7,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/2542\/revisions"}],"predecessor-version":[{"id":2998,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/posts\/2542\/revisions\/2998"}],"wp:attachment":[{"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/media?parent=2542"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/categories?post=2542"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raxdoors.com\/de\/wp-json\/wp\/v2\/tags?post=2542"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}